Results 241 to 250 of about 825,035 (300)
Small but systematic bias introduced by EEG electrodes in PET imaging
Stöhrmann P +14 more
europepmc +1 more source
Fabrication of arc-shaped 3D electrodes for biomedical devices
We developed a simple, low-cost and novel method for constructing three dimensional (3D) microelectrodes in biomedical devices by utilizing low melting point metal alloy. Three dimensional electrodes have unique properties in biomedical applications such as cell lysis, electroporation, dielectrophoresis, and detection.
Weihua Li
exaly +3 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
IEEE Transactions on Biomedical Engineering, 2005A low electrode-electrolyte impedance interface is critical in the design of electrodes for biomedical applications. To design low-impedance interfaces a complete understanding of the physical processes contributing to the impedance is required. In this work a model describing these physical processes is validated and extended to quantify the effect of
Andreas Hierlemann +2 more
exaly +5 more sources
Recent advances in electrode development for biomedical applications
Biomedical Engineering Letters, 2021Elaborate electrodes that enable adhesion to the skin surface and effectively collect vital signs are necessitated. In recent years, various electrode materials and novel structures have been developed, and they have garnered scientific attention due to their higher sensing performances compared with those of conventional electrode-based sensors.
Eun Kwang Lee +4 more
openaire +2 more sources
Capacitive Type of Biomedical Electrode
IEEE Transactions on Biomedical Engineering, 1970A suitable dielectric for a capacitive biomedical electrode is presented. In application a thin (2-mil) film of pyre varnish is deposited on the electrode surface and heat cured. Capacitance values of 800 pF for a 0.5-inch-diameter electrode are typical.
A, Potter, L, Menke
openaire +2 more sources
Numerical Modelling of Capacitive Electrodes for Biomedical Signals Measurement
2021 44th International Convention on Information, Communication and Electronic Technology (MIPRO), 2021Surface electromyography (sEMG) uses noninvasive technique of measuring muscle action potentials on the skin surface. Numerical methods are often the first step in such a process of electrodes and biomedical electronic systems design. Thoughtful simulation, that precedes physical implementation, may speed up the product development, foreseeing its ...
Luka Klaic +2 more
openaire +2 more sources
Manganese dioxide depolarizer for biomedical electrodes
Medical & Biological Engineering, 1970The electrochemical and toxicological characteristics of manganese dioxide (MnO2) have been described. Details of the construction and testing of surface MnO2 electrode are presented. The reported data and the results of tests confirm that a MnO2 electrode sufficiently stable and free from polarization effects can be constructed.
R, Nencini, E, Pasquali
openaire +2 more sources
Development of a miniaturepCO2 electrode for biomedical applications
Medical & Biological Engineering, 1975A miniaturepCO2 electrode for possible CO2 measurement in a biological system was constructed and evaluated. ThepCO2 electrode employed a miniature pH glass electrode and the Severinghaus configuration. The electrode was evaluated in both gas and liquid phases. A good linear relation existed between the measured electrode potential of thepCO2 electrode
N C, Lai +4 more
openaire +2 more sources
Mobile biomedical sensing with dry electrodes
2008 International Conference on Intelligent Sensors, Sensor Networks and Information Processing, 2008Monitoring patients continuously while they go about their daily activities is a challenging goal. It requires long-term recording of cardiovascular and other electrophysiological signals and contextual information such as body motion. Here we present a small, battery powered, user customisable, portable monitor capable of recording three-axial ...
Gargiulo G +5 more
openaire +2 more sources

