Infective Endocarditis Diagnosed by Emergency Physicians Using Cardiac POCUS: A Case Series
ABSTRACT Introduction Emergency physicians (EPs) are acquiring ever‐increasing expertise in cardiac point‐of‐care ultrasound (POCUS). We compiled this case series to demonstrate current practice by EPs diagnosing infective endocarditis (IE) using POCUS.
Jonathan Henry +8 more
wiley +1 more source
Effect of pregnancy on bioprosthetic structural valve degeneration
Background: Despite increasing frequency of pregnancies among patients with cardiac conditions, including the presence of prosthetic heart valves, data on the effects of physiological changes during pregnancy on the function of bioprosthetic valves ...
Joshua J. Price +4 more
doaj +1 more source
Late thrombosis of a mitral bioprosthetic valve with associated massive left atrial thrombus
An 84-year-old man presented 5 years after bioprosthetic mitral valve replacement with three months of worsening dyspnea on exertion. A new mitral stenosis murmur was noted on physical examination, and an electrocardiogram revealed newly recognized ...
Preetham R Muskula +3 more
doaj +1 more source
Untreatable Severe Structural Degeneration of a Transcatheter Aortic Heart Valve
We describe a patient who presented with heart failure 7 years post-transcatheter aortic valve implantation (TAVI) as a result of severe structural valve degeneration.
Noman Ali, PhD +4 more
doaj +1 more source
ABSTRACT Background The EMPIRE I study assessed the early (30 days) safety and efficacy of a new fully repositionable delivery system (IMPERIA) for the commercially available ALLEGRA transcatheter aortic valve in patients with either severe native aortic stenosis or a degenerated surgical bioprosthesis.
José Antonio Baz +15 more
wiley +1 more source
Microaxial Flow Pump Support as a Bridge to Transaxillary TAVI‐In‐TAVI in Cardiogenic Shock
ABSTRACT A 79‐year‐old man presented with cardiogenic shock due to severe degeneration of a prior transcatheter aortic valve. Temporary mechanical circulatory support with a transvalvular microaxial flow pump was initiated, resulting in rapid stabilization.
Matteo Orlandi +9 more
wiley +1 more source
Clinical outcomes after implantation of bioprosthetic valves in adults with congenital heart disease
Background: Bioprosthetic valves are frequently implanted in adults with congenital heart disease (CHD), but comprehensive data on bioprosthetic valve longevity and outcomes across all valve positions are lacking.
Andrea R. Hsu +10 more
doaj +1 more source
Comparison of mechanical versus bioprosthetic valve replacement in mitral stenosis surgery
Background Mitral stenosis is a common valvular heart disease, and the choice of valve material during surgical treatment significantly impacts patient prognosis.
Jinfeng Ma, Qingming Xue
doaj +1 more source
Early Structural Valve Deterioration and Cusp Tear Leading to Acute Heart Failure in a Second-Generation Trifecta Glide Technology Heart Valve [PDF]
This report highlights a case of early structural valve deterioration with a cusp tear in a second-generation Abbott Trifecta Glide Technology bioprosthetic heart valve.
Akiyoshi Yamamoto, MD +3 more
doaj +1 more source
Cardiac crossroads: deciding between mechanical or bioprosthetic heart valve replacement
Maggie N Tillquist1, Thomas M Maddox21School of Medicine, University of Colorado Denver, Denver, CO, USA; 2VA Eastern Colorado Health Care System, and Department of Medicine (Cardiology), University of Colorado Denver, Denver, CO, USAAbstract: Nearly 15 ...
Thomas M Maddox, Maggie N Tillquist
core