Results 1 to 10 of about 809 (88)
Imaging of Bioprosthetic Valve Dysfunction after Transcatheter Aortic Valve Implantation
Transcatheter aortic valve implantation (TAVI) has become the standard of care in elderly high-risk patients with symptomatic severe aortic stenosis. Recently, TAVI has been increasingly performed in younger-, intermediate- and lower-risk populations ...
Fabien Praz, Thomas Pilgrim
exaly +3 more sources
Performance of xenogeneic pulmonary visceral pleura as bioprosthetic heart valve cusps in swine
ObjectiveBovine pericardium is common biological material for bioprosthetic heart valve. There remains a significant need, however, to improve bioprosthetic valves for longer-term outcomes.
Xiao Lu +5 more
doaj +1 more source
Very little is known about the occurrence of bioprosthetic tricuspid valve stenosis in the Indian population that usually occurs within 8–10 years following tricuspid valve replacement (TVR) with a bioprosthetic valve.
Ganeshrao Patilba Sapkal +1 more
doaj +1 more source
Background Mechanisms underlying bioprosthetic valve deterioration are multifactorial and incompletely elucidated. Reparative circulating progenitor cells, and conversely calcification‐associated osteocalcin expressing circulating progenitor cells, have ...
Yoshihisa Kanaji +7 more
doaj +1 more source
Currently, transcatheter aortic valve replacements within degenerated surgical bioprosthetic aortic valves (valve in valve) are increasing in frequency with studies supporting their safety and efficacy.
Muhammad Ajmal +4 more
doaj +1 more source
Porcine or Bovine Tissue Valves: Which are Better for Surgical Aortic Valve Replacement? [PDF]
The choice between mechanical and bioprosthetic aortic valve implants is affected by relatively clear criteria. However, the choice between porcine or pericardial valve is more complex regarding bioprosthetic devices.
Georgi Manchev +4 more
doaj +3 more sources
Intracardiac Echocardiography to Diagnose Bioprosthetic Pulmonary Valve Thrombosis
A 48-year-old woman presented with heart failure and bioprosthetic pulmonary valve regurgitation 2 years after pulmonary valve replacement. Intracardiac echocardiography demonstrated uniform thickening of a single prosthetic valve leaflet suggesting ...
Christopher J. DeZorzi, MD +4 more
doaj +1 more source
Introduction. We present the clinical observation of a 72-year-old female patient with high surgical risk and structural degeneration of a bioprosthetic aortic valve (AV) cusps in the form of stenosis, accompanied by severe dysfunction.
L. S. Kokov +5 more
doaj +1 more source
Management of Failed Bioprosthetic Aortic Valves: Mitigating Complications and Optimizing Outcomes
The use of bioprosthetic prostheses during surgical aortic valve replacements has increased dramatically over the last two decades, accounting for over 85% of surgical implantations.
Elizabeth L. Norton +3 more
doaj +1 more source
Unexpected bioprosthetic mitral valve thrombus during left ventricular assist device implantation
Acute bioprosthetic valve thrombosis can occur after surgery and sometimes cause hemodynamic instability and cardiogenic shock. Risk factors for bioprosthetic valve thrombosis are hypercoagulability, atrial fibrillation, atrial dilatation, low cardiac ...
Tatsuyuki Imada +3 more
doaj +1 more source

