Results 111 to 120 of about 329,528 (297)

Long‐Term Follow‐Up of the S‐ICD: A 10‐Years Follow‐Up Study of a Large Single Center Cohort

open access: yesPacing and Clinical Electrophysiology, Volume 48, Issue 4, Page 443-446, April 2025.
ABSTRACT Background The subcutaneous implantable defibrillator (S‐ICD) is an alternative to transvenous implantable defibrillators. The present analysis presents real‐world data from patients with S‐ICD and a follow‐up duration of 10 years or more. Methods and Results Between July 2010 and November 2013 76 S‐ICD systems were implanted.
Gerrit Frommeyer   +7 more
wiley   +1 more source

Strategies to Reduce Heart Failure Hospitalizations and Readmissions: How Low Can We Go?

open access: yesCardiovascular Innovations and Applications, 2015
It is estimated that more than one million heart failure hospitalizations occur each year. Systolic heart failure and heart failure with preserved ejection fraction contribute equally to heart failure hospitalizations.
Juan M. Aranda
doaj   +1 more source

Successful Retrieval of a 4-Year-Old Micra Transcatheter Pacemaker System in a Patient With Leadless Biventricular Pacing Therapy

open access: yesJACC: Case Reports, 2020
This is the first report of the management of a patient with cardiac resynchronization therapy using leadless biventricular pacing. Successful retrieval of a 4-year-old Micra transcatheter pacing system (TPS) and reimplantation of a new Micra TPS ...
Kentaro Minami, MD   +10 more
doaj  

A Self-Paced Regularization Framework for Multi-Label Learning [PDF]

open access: yesarXiv, 2016
In this paper, we propose a novel multi-label learning framework, called Multi-Label Self-Paced Learning (MLSPL), in an attempt to incorporate the self-paced learning strategy into multi-label learning regime. In light of the benefits of adopting the easy-to-hard strategy proposed by self-paced learning, the devised MLSPL aims to learn multiple labels ...
arxiv  

Biventricular Pacing Decreases Sympathetic Activity Compared With Right Ventricular Pacing in Patients With Depressed Ejection Fraction [PDF]

open access: bronze, 2000
Mohamed H. Hamdan   +7 more
openalex   +1 more source

The QT measurements after biventricular pacing, is it reliable?

open access: yesJournal of the Saudi Heart Association, 2014
Dear Editor, We read the article ‘Potential pro-arrhythmic effect of cardiac resynchronization therapy’ by Tayeh et al. with great interest [1]. The authors showed a significant decrease in QRS duration but significant prolongation in corrected QT interval after bi-ventricular pacing (CRT).
Sait Demirkol   +5 more
openaire   +3 more sources

Integrating anatomy and electrophysiology in the healthy human heart: Insights from biventricular statistical shape analysis using universal coordinates [PDF]

open access: yesarXiv
A cardiac digital twin is a virtual replica of a patient-specific heart, mimicking its anatomy and physiology. A crucial step of building a cardiac digital twin is anatomical twinning, where the computational mesh of the digital twin is tailored to the patient-specific cardiac anatomy.
arxiv  

Randomized Trial of Left Bundle Branch vs Biventricular Pacing for Cardiac Resynchronization Therapy.

open access: yesJournal of the American College of Cardiology, 2022
Yao Wang   +20 more
semanticscholar   +1 more source

Mid‐term results of biventricular pacing for heart failure: Correlation between clinical and hemodynamic data [PDF]

open access: bronze, 2000
Stéphane Garrigue   +6 more
openalex   +1 more source

Home - About - Disclaimer - Privacy