FC09 Biventricular pacing for heart failure — mechanisms of action [PDF]
Jens Cosedls +14 more
openalex +1 more source
P-240 Increasing hemodynamic benefit at unchanged degree of resynchronization during chronic biventricular pacing in canine LBBB hearts [PDF]
Xander Verbeek +4 more
openalex +1 more source
Effect of Biventricular Pacing on Diastolic Dyssynchrony
This study sought to examine the changes in diastolic dyssynchrony with cardiac resynchronization therapy (CRT).Little is known about the effect of CRT on diastolic dyssynchrony.Consecutive heart failure patients (n = 266, age 65.7 ± 10.0 years) underwent color-coded tissue Doppler imaging at baseline, 48 h, and 6 months after CRT.
Shanks M. +10 more
openaire +6 more sources
Haemodynamic consequences of targeted single- and dual-site right ventricular pacing in adults with congenital heart disease undergoing surgical pulmonary valve replacement [PDF]
Aims The purpose of this study was to create an epicardial electroanatomic map of the right ventricle (RV) and then apply post-operative-targeted single- and dual-site RV temporary pacing with measurement of haemodynamic parameters.
Bolger, AP +10 more
core +2 more sources
Influence of heart failure etiology on the effect of upgrading from right ventricular apical to biventricular or bifocal pacing in patients with permanent atrial fibrillation and advanced heart failure [PDF]
Barbara Małecka +3 more
openalex +1 more source
The case of cardiac biventricular resynchronization without destruction of the atrio-ventricular node in patients with chronic heart failure (CHF) and permanent atrial fibrillation (AF) is described. The observation period was 14 months.
I. V. Shanina, D. E. Volkov, D. A. Lopin
doaj
Conduction system pacing is widely used as an alternative to right ventricular pacing and, in some cases, as an alternative to biventricular pacing for cardiac resynchronization therapy. Proper programming of an implantable electronic device is essential
V. K. Lebedeva
doaj +1 more source
Effective cardiac resynchronization therapy (CRT) requires an accurate atrio-biventricular pacing system. The innovative Quartet lead is a quadripolar, over-the-wire left ventricular lead with four electrodes and has recently been designed to provide ...
Mariana S. Parahuleva +6 more
doaj +1 more source
The effect of ventricular sequential contraction on helical heart during pacing: high septal pacing versus biventricular pacing [PDF]
Hideyuki Tomioka +5 more
openalex +1 more source
New Insights into Pacing Induced Cardiomyopathy
Pacing induced cardiomyopathy (PICM) can occur as a complication due to pacing the right ventricle. Its precise definition varies across different studies, leading to uncertainty as to the best approach for managing this entity. More than 10% of patients
Sung Soo Kim, Hyung Wook Park
doaj +1 more source