Results 321 to 330 of about 52,618 (383)
Some of the next articles are maybe not open access.

Bleb reduction and bleb repair after trabeculectomy

Ophthalmology, 2000
To describe methods and outcomes for repair of bleb-related complications of trabeculectomy surgery.Retrospective, consecutive, noncomparative case series.Thirty-one persons having bleb revision by two surgeons at the Wilmer Institute from 1994 to the present.One of two types of revision surgery was performed: bleb reduction to decrease symptoms from ...
S E, La Borwit   +2 more
openaire   +2 more sources

Bleb Plication for a Leaking Bleb After Trabeculectomy

Journal of Glaucoma, 2020
Purpose: The purpose of this work was to report a new method for the repair of ischemic bleb leaks. Bleb leakage is a serious complication of glaucoma filtering surgery with mitomycin C. Many surgical methods have been proposed to seal the leakage from a bleb; however, this novel plication method is effective, relatively easy ...
Koichiro, Sugimoto   +4 more
openaire   +2 more sources

Leaking Filtering Blebs

American Journal of Ophthalmology, 1978
Histologic examination of ten leaking filtering blebs revealed an epithelial tract running from the surface of the bleb down to the episclera in eight cases. These epithelial tracts were considered the real cause of the persistent leakage.
Z, Sinnreich, R, Barishak, R, Stein
openaire   +2 more sources

Pericardium Patch Graft (Tutoplast) for Bleb Repair and Bleb Remodelling After Nonpenetrating Filtering Surgery: 6-Month Outcomes

Journal of glaucoma, 2020
Purpose: The purpose of this study was to evaluate the outcome of pericardium patch graft (Tutoplast) as an adjuvant to either bleb repair or bleb reduction after nonpenetrating filtering surgery.
L. Niegowski   +4 more
semanticscholar   +1 more source

Encapsulated Filtering Blebs

Archives of Ophthalmology, 1987
Les bulles encapsulees ou «kystes» de la capsule de Tenon sont classiquement associes a une elevation de la pression intraoculaire apres chirurgie filtrante du glaucome. Cependant, cette elevation n'est pas toujours presente.
R M, Feldman   +5 more
openaire   +2 more sources

Bleb-Limiting Conjunctivoplasty for Symptomatic Circumferential Trabeculectomy Blebs

Journal of Glaucoma, 2003
To describe a new surgical technique for limiting symptomatic circumferential conjunctival blebs, an uncommon complication after trabeculectomy.Four eyes of 2 patients underwent conjunctivoplasty to limit the extent of symptomatic circumferential blebs.
R, Rahman, V T, Thaller
openaire   +2 more sources

Bleb Morphology After Mitomycin-C Augmented Trabeculectomy: Comparison Between Clinical Evaluation and Anterior Segment Optical Coherence Tomography

Journal of glaucoma, 2019
Purpose: The main aim of this article was to study the longitudinal correlation between the clinical, morphological appearance of filtering blebs with anterior segment optical coherence tomography (AS-OCT) in the early postoperative period.
Soeren Waibel   +4 more
semanticscholar   +1 more source

Dysfunctional Filtering Blebs

Survey of Ophthalmology, 1998
Guarded filtration surgery, is commonly used to control the intraocular pressure (IOP) in glaucomatous patients. Filtration surgery lowers the IOP by creating a fistula between the inner compartments of the eye and the subconjunctival space (i.e., filtering bleb). There are several options to improve the function of filtering blebs and to prevent their
Azuara-Blanco, A., Katz, L.J.
openaire   +3 more sources

Changes in filtering bleb morphology after bleb-related infection

Japanese Journal of Ophthalmology, 2015
To verify, by use of data collected by the Japan Glaucoma Society Survey of Bleb-related Infection (JGSSBI), that bleb morphology changes within 12 months of the development of bleb-related infection.JGSSBI data from 57 eyes of 57 patients with primary open-angle glaucoma and normal tension glaucoma who developed a bleb-related infection were analyzed.
Akira, Sawada   +2 more
openaire   +2 more sources

Comparison of Efficacy and Safety of Bleb Needle Revision With and Without 5-Fluorouracil for Failing Trabeculectomy Bleb

Journal of glaucoma, 2019
Précis: Bleb needle revision with and without 5-FU showed similar success rates over the course of a long-term follow-up. A greater total number of needle revisions was identified as a risk factor for procedural failure. Purpose: The purpose of the study
Jin-soo Kim   +5 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy