Treatment of Postfiltration Bleb Leak by Bleb Injection of Autologous Blood
Ophthalmic Surgery Lasers and Imaging Retina, 1994ABSTRACT We treated a persistent, brisk bleb-leak after trabeculectomy with mitomycin C by bleb injection of autologous blood. Following preparation with povidone iodine, approximately 0.5 cc of whole autologous blood was injected into the bleb at the slit lamp.
M F, Smith, R, Magauran, J W, Doyle
exaly +3 more sources
Graefe's Archive for Clinical and Experimental Ophthalmology, 2012
To determine the incidence of late-onset bleb leak (BL), blebitis (B) and bleb-related endophthalmitis (BRE) after trabeculectomy surgery, and report the management approaches employed by UK ophthalmologists.Prospective case ascertainment study reporting of incident cases fulfilling the study definitions of BL, B and BRE through the reporting mechanism
Anthony King
exaly +3 more sources
To determine the incidence of late-onset bleb leak (BL), blebitis (B) and bleb-related endophthalmitis (BRE) after trabeculectomy surgery, and report the management approaches employed by UK ophthalmologists.Prospective case ascertainment study reporting of incident cases fulfilling the study definitions of BL, B and BRE through the reporting mechanism
Anthony King
exaly +3 more sources
Simmons' Tamponade Shell for Leaking Filtration Blebs
Archives of Ophthalmology, 1985We used the Simmons' tamponade shell to successfully treat four of five patients who had leaking filtration blebs after glaucoma surgery. Bleb leaks in both the immediate postoperative period as well as many years following surgery were treated. In each case, previous pressure patching had been unsuccessful.
J M, Ruderman, R C, Allen
openaire +2 more sources
A Surgical Method to Repair Leaking Filtering Blebs
Ophthalmic Surgery, Lasers and Imaging Retina, 1992ABSTRACT Surgical revision of a chronically-thinned filtering bleb with a leak at the limbus is described. After surgical excision of the scarred cystic conjunctiva and Tenon's fascia surrounding the leaking bleb, relatively uninvolved conjunctiva and Tenon's fascia are mobilized with the help of a large relaxing incision in the superior ...
D J, O'Connor +2 more
openaire +2 more sources
Bleb reconstruction using donor scleral patch graft for late bleb leak and hypotony
European Journal of Ophthalmology, 2020Purpose Bleb dysfunction may occur as a late complication following glaucoma filtration surgery. Over-filtering, thinning and cystic blebs can lead to hypotony, leak and corneal dellen. We report our surgical management and outcomes of this specific entity using donor scleral patch grafts.
Michael O’Rourke +3 more
openaire +2 more sources
2009
Controversy exists regarding the effect of early postoperative bleb leaks on trabeculectomy outcomes. The Flourouracil Filtering Surgery Study found that early wound leaks were strongly associated with failure [29]. However, other authors have not found this association, though the number of leaks in their studies was small [1, 9, 18]. In my experience,
openaire +1 more source
Controversy exists regarding the effect of early postoperative bleb leaks on trabeculectomy outcomes. The Flourouracil Filtering Surgery Study found that early wound leaks were strongly associated with failure [29]. However, other authors have not found this association, though the number of leaks in their studies was small [1, 9, 18]. In my experience,
openaire +1 more source
Long-term results of amniotic membrane transplantation-assisted bleb revision for leaking blebs
Graefe's Archive for Clinical and Experimental Ophthalmology, 2007To report long-term results of amniotic membrane transplantation (AMT)-assisted bleb revision for intractable late-onset bleb leak.Retrospective medical record review of six consecutive patients who underwent AMT-assisted bleb revision for late-onset bleb leak at the Kobe University hospital between December 2001 and March 2004.The median (range) of ...
Makoto Nakamura, Akira Negi
exaly +3 more sources
Repair of an Inadvertent Buttonhole or Leaking Filtering Bleb
Archives of Ophthalmology, 1979Buttonholing of conjunctival flaps at the time of filtering glaucoma surgery or a leak in the flap postoperatively can cause serious problems and may be most difficult to repair. A new delicate atraumatic needle has been used successfully in five cases to close conjunctiva to conjunctiva or conjunctiva to cornea defects.
G J, Petursson, F T, Fraunfelder
openaire +2 more sources
Outcomes of Surgical Bleb Revision for Late-onset Bleb Leaks After Trabeculectomy
Journal of Glaucoma, 2013To describe the outcome of surgical bleb revision for late-onset bleb leaks after trabeculectomy.Appropriate cases were identified. Qualified and complete success required intraocular pressure of 21 mm Hg or less with and without glaucoma medication use, respectively.
Albert P, Lin +6 more
openaire +2 more sources
Severe Cough: A Cause of Late Bleb Leak
Journal of Glaucoma, 2003To highlight coughing as a potential cause for late postoperative trabeculectomy bleb leaks.A retrospective study of 2 patients in whom late bleb leaks developed after a bout of severe coughing. Perioperative 5-fluorouracil was used at the time of the initial filtration procedure for one of the patients, while the second patient had had an ordinary ...
Asifa, Shaikh +2 more
exaly +3 more sources