Results 81 to 90 of about 68,991 (147)
Leak detection, calibrations and reference flows: Practical example
The most diffused leak detection method for the leak rates lower than 10(-2) mbarL/s that is based on the application of mass spectrometry with tracer gas (generally helium) is considered.
MARI, DOMENICO GIANLUCA +2 more
core +1 more source
Hideto Sagara,1,2 Tetsuju Sekiryu,2 Hiroki Noji,2 Masashi Ogasawara,2 Kimihiro Imaizumi,2 Keiko Yago31The Marui Eye Clinic, Minamisoma, 2Department of Ophthalmology, School of Medicine, Fukushima Medical University.
Sagara H +5 more
doaj
PURPOSE: To describe the outcome of various treatment modalities in the management of late bleb leaks after glaucoma filtering surgery (GFS). MATERIALS AND METHODS: Seven consecutive patients treated for late bleb leaks (Seidel′s positive) between
Mandal A
doaj
Purpose: The aim of this study was to introduce a reproducible algorithm for the surgical management of late-onset (>2 months) bleb complications after trabeculectomy with mitomycin C. Methods: We performed a retrospective review of eyes treated using
Oportus, María J. +17 more
core +1 more source
PURPOSE: To describe the late onset of sequential multifocal bleb leaks as a postoperative complication after filtering surgery with antimetabolites.
Belyea, D. A. +4 more
core +1 more source
"May I propose a toast?" [picture] /
Part of the collection: Matilda collection.; Drawing signed by artist lower right.; Published in: "Ballistics", Roger Wagstaff. Matilda. Canberra : Dynwest, no. 10, Feb. 1986, p. 49.; Matilda Gallery caption: May I propose a toast?
Leak, Bill, 1956-
core
Leak rate metrology for the society and industry
Leak detection is a non-destructive test performed to verify materials and components in agreement with the prescribed specifications, by using techniques, which do not damage their characteristics or performances.
MARI, DOMENICO GIANLUCA +3 more
core +1 more source
Purpose The introduction of anti-metabolite regimens to glaucoma filtration surgery has improved post-operative intraocular pressure (IOP) control; however, it has also increased the frequency of dysfunctional blebs.
Holcombe, DJ +3 more
core +1 more source
88th Annual Meeting of the Meteoritical Society 2026: Abstracts
Meteoritics &Planetary Science, Volume 61, Issue S1, Page S48-S551, August 2026.
wiley +1 more source
Hideto Sagara,1,2 Tomohiro Iida,2,3 Kimimori Saito,4 Hiroki Noji,2 Masashi Ogasawara,2 Hiroshi Oyamada21The Marui Eye Clinic, Fukushima, 2Department of Ophthalmology, Fukushima Medical University School of Medicine, Fukushima, 3Tokyo Women's ...
Sagara H +5 more
doaj

