Results 121 to 130 of about 3,784 (194)

Deformation and strength of grouted sleeve connectors in pre‐fabricated concrete structures: Mechanisms and analytical modeling

open access: yesStructural Concrete, EarlyView.
Abstract Grouted sleeve connectors (GSCs) are widely used in precast/prefabricated concrete structures. To ensure force transfer, connectors are often overdesigned in length. This practice has an unintended consequence of reducing the plastic deformation capacity of the connection region and hence the displacement ductility of the precast structure as ...
Hongning Ye, Yong Lu
wiley   +1 more source

Regression‐based models for the torsional stiffness reduction factor in reinforced concrete beams under combined torsion and shear

open access: yesStructural Concrete, EarlyView.
Abstract This paper presents a regression‐based methodology to estimate the Torsional Stiffness Reduction Factor (TSRF) of reinforced concrete beams under combined torsion and shear. A numerical database of 6816 samples was generated using the Combined Action Softened Truss Model (CA‐STM) implemented in Python, considering design guidelines prescribed ...
Khrys K. S. Medeiros   +2 more
wiley   +1 more source

ANPGT: Towards Adaptive Node Property Extraction and Integration

open access: yesCAAI Transactions on Intelligence Technology, EarlyView.
ABSTRACT Graph transformers (GTs) with elaborate positional/structural encodings (PEs/SEs) have excelled in graph representation learning, especially in graph‐level tasks. However, their potential in large‐scale node classification remains untapped for several reasons: (i) Current PEs/SEs are insufficient in modelling large‐scale real‐world graphs ...
Qin Chen   +4 more
wiley   +1 more source

Mechanism of Quasi‐Power‐Frequency Resonant Overvoltage Triggered by Multiple Lightning Strikes in High‐Voltage Alternating Current Systems Equipped With Shunt Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang   +7 more
wiley   +1 more source

High‐purity X‐ray polarimetry at high energies for Mössbauer spectroscopy

open access: yesJournal of Synchrotron Radiation, EarlyView.
This work extends high‐purity X‐ray polarimetry into the 15–30 keV range, enabling polarization‐filtered synchrotron Mössbauer spectroscopy of higher‐energy nuclear resonances. A proof‐of‐principle experiment at 22.494 keV demonstrates a polarization purity of (1.2 ± 0.5) × 10−8, establishing the feasibility of the approach.High‐purity X‐ray ...
Berit Marx-Glowna   +9 more
wiley   +1 more source