Results 151 to 160 of about 365,373 (345)

A Portrait of Cord Blood Units Distributed for Transplantation from Canadian Blood Services’ Cord Blood Bank: First Analysis [PDF]

open access: gold, 2022
Gaganvir Parmar   +9 more
openalex   +1 more source

PARPi Combining Nanoparticle LIN28B siRNA for the Management of Malignant Ascites

open access: yesAdvanced Science, EarlyView.
This study demonstrates that co‐inhibition of LIN28B and PARP using siLin28b/DSSP@lip‐PEG‐FA nanoparticles in combination with the PARP inhibitor BMN673 effectively suppresses the accumulation of malignant ascites associated with advanced cancers.
Yan Fang   +13 more
wiley   +1 more source

Plasma as alternatively sample to quantify tetanus antitoxin

open access: yesVacciMonitor, 2015
Tetanus antitoxin is quantified in Cuba at blood banks, from the serum of immunized donors, to produce aspecific human gamma globulin. A heterogeneous indirect immunoenzymatic assay is used, using the serum as analytical sample.
Ariel Menéndez-Barrios   +5 more
doaj  

Assessment of Performance of Blood Banks in India: A National Level Cross Sectional Study. [PDF]

open access: yesIndian J Hematol Blood Transfus, 2021
Asirvatham ES   +6 more
europepmc   +1 more source

Astrocytic PERK Deficiency Drives Prefrontal Circuit Dysfunction and Depressive‐Like Behaviors

open access: yesAdvanced Science, EarlyView.
Chen et al. show that the endoplasmic reticulum (ER) stress sensor PERK is downregulated in prefrontal cortex (PFC) astrocytes in major depressive disorder and in chronic‐stress mouse models. In young mice, astrocyte‐specific PERK loss reduces the synaptogenic cue thrombospondin‐1 (TSP1), leading to synaptic and circuit deficits and depressive‐like ...
Kai Chen   +8 more
wiley   +1 more source

Perspectives and attitudes to voluntary blood donation in a tertiary referral hospital blood bank

open access: diamond, 2013
Umakanth Siromani   +4 more
openalex   +1 more source

Rapid Microfluidic Drug Sensitivity Testing Within 5 Days Using Minimal Clinical Tumor Samples

open access: yesAdvanced Science, EarlyView.
This study develops the air‐punched fabrication approach for nanoliter‐scale microcavity arrays with ultra‐smooth microcavity surfaces, with which rapid formation and 3D culture of tumor cell spheroids from small numbers of cell samples, as well as high‐throughput drug sensitivity testing can be achieved within 5 days.
Yi‐Xue Chen   +11 more
wiley   +1 more source

A Biomarker‐Driven Ovary–Endometrium Organ‐on‐a‐Chip Mimicking 3D Multicellular Complexity and Menstrual Cyclicity for Predicting Reproductive Toxicity

open access: yesAdvanced Science, EarlyView.
We present a dual‐organ, biomarker‐integrated ovaryendometrium organ‐on‐a‐chip that recapitulates 3D tissue complexity, menstrual cycle dynamics, and hormonal crosstalk. This platform enables real‐time, cell‐typespecific fluorescent readouts of reproductive toxicity using ANGPTL4 and SERPINB2 as early‐response reporters.
Soo‐Rim Kim   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy