Reduced compression time is not sufficient for stability in patellar buttons
Abstract Purpose Patellar resurfacing in total knee arthroplasty requires stable cement fixation of the patellar button. Unlike femoral and tibial components, the patellar button is held under manual compression until cement curing, potentially prolonging operative time.
Leandra Bauer +5 more
wiley +1 more source
Abstract Purpose Introduction of new components in total knee arthroplasty (TKA) should be assessed for long‐term stability. The primary objective was to determine whether migration of a new cementless tibial baseplate in kinematically aligned (KA) TKA is below the 6‐month threshold where baseplates have a low incidence of long‐term loosening.
Rubiana Monteiro +4 more
wiley +1 more source
Abstract Purpose While patient‐level factors for prosthetic joint infections (PJIs) following total knee arthroplasty (TKA) are well‐established, prior ipsilateral knee procedures are typically treated as a uniform risk factor despite likely variation in risk profile across procedure types.
Randa Elsheikh +4 more
wiley +1 more source
Abstract Purpose To compare residual symptoms, function and patient satisfaction following unrestricted kinematic alignment (KA) versus mechanical alignment (MA) in primary total knee arthroplasty (TKA). It was hypothesized that KA would reduce residual symptoms and improve function and satisfaction.
Stefano Campi +10 more
wiley +1 more source
Abstract Purpose Magnetic resonance imaging (MRI) frequently detects lateral compartment abnormalities in patients considered for medial unicompartmental knee replacement (UKR). The long‐term prognostic significance of these findings remains unclear and may influence patient selection.
Kristine Ifigenia Bunyoz +5 more
wiley +1 more source
Abstract Purpose To evaluate functional outcomes and implant survival following medial unicompartmental knee arthroplasty (UKA) in patients with anteromedial osteoarthritis and preoperative varus deformity ≥10° and to identify postoperative alignment thresholds that optimize outcomes.
Johannes Weishorn +7 more
wiley +1 more source
Clinical application of controllable bone cement injection during percutaneous vertebroplasty. [PDF]
Chen Y +5 more
europepmc +1 more source
ABSTRACT Purpose Gap‐filled zero echo time (ZTE) acquisitions combined with dedicated short‐T2 hardware enable direct collagen imaging on the timescale of macromolecular (MM) signals, with T2s ˜ 10 μs. However, present methods offer limited depiction fidelity, and their specificity towards MM content is poorly understood. This work presents methodology
Jason Daniel van Schoor +3 more
wiley +1 more source
Bone Cement Leakage-Induced Pulmonary Embolism: A Case Report. [PDF]
Xv Y, Bo Y.
europepmc +1 more source
Cross-linked Acrylic Bone Cement with Biodegradable Additives
In order to enhance of 3-D polymer structure bone cement biocompatibility, the cement on the base of poly(MMA-hexylacrylate)-ethylmethacrylate-triethyleneglycol dimethacrylate has been modified by the introduction of biodegradable additives. Chitosan and
Krilova, Valentīna +3 more
core