Results 201 to 210 of about 28,897 (262)
The Application of Telemedicine in Surgery
This figure provides an overview of the content presented in this article. Telemedicine is integrated throughout the entire surgical workflow, with distinct applications across the preoperative, intraoperative, and postoperative phases. These applications are enabled by a suite of supporting technologies, while the associated implementation challenges ...
Yufan Yang +8 more
wiley +1 more source
Comprehensive Analysis and Surgical Management of Neglected Congenital Talipes Equinovarus Using the Joshi's External Stabilizing System: A 3-Year Longitudinal Case Study and Biomechanical Review. [PDF]
Subramaniyan VS +4 more
europepmc +1 more source
Targeted Muscle Reinnervation for Intuitive Prosthetic Control
ABSTRACT The convergence of medical and technological advances has led to a substantial expansion of therapeutic approaches for patients with limb amputations. Targeted muscle reinnervation (TMR) is one of the strategies to improve control of bionic arms and has been applied for more than two decades. Through surgical rewiring of the nerves responsible
Nitay Maile +5 more
wiley +1 more source
Abstract Objective To investigate effects of repeated training with anatomically varied versus identical 3D‐printed models on skill acquisition, cognitive load, and skill retention in novice mastoidectomy trainees. Study Design A prospective, randomized, controlled, educational trial conducted April to September 2024 including a 3‐month retention test.
Adam Omari +4 more
wiley +1 more source
The Audiologic and Otolaryngologic Phenotype in WHIM Syndrome
Abstract Objective WHIM syndrome (warts, hypogammaglobulinemia, infections, and myelokathexis syndrome) is an ultra‐rare primary immunodeficiency disease caused by autosomal dominant hyperfunctional mutations in the chemokine receptor CXCR4. Otolaryngologists are frequently consulted to evaluate WHIM patients because of recurrent acute ear and sinus ...
Christopher K. Zalewski +7 more
wiley +1 more source
Electrospun conducting polymers: recent trends and the transition towards a sustainable future
This review discusses the electrospinning of conducting polymers, detailing procedures, fibrous morphologies, improved properties, applications in electronics, and challenges, while outlining future directions for nanofibre‐based devices in various fields.
Xenofon Karagiorgis +3 more
wiley +1 more source
Abstract Background The prosthetic socket is central to the comfort, function, and satisfaction for lower‐limb prosthesis users. Traditional fixed‐geometry sockets offer limited adjustability and sometimes fail to accommodate daily changes in residual limb volume or shape, leading to poor load distribution, discomfort, skin issues, and reduced quality ...
Dwiesha L. England +7 more
wiley +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Forces Generated in Guide-Wires when Drilling Human Bone
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1995In orthopaedic surgery guide-wires are extensively used for the drilling of pilot holes in human bones to allow further drilling, reaming and screw-tapping to take place in the repair and reconstruction of fractures. The guide-wires are generally 1.5 to 2.5 mm in diameter and have a three-faceted point with or without a screw thread.
I, Shuaib, M, Hillery
exaly +3 more sources
Acta Orthopaedica, 1993
Laboratory tests were carried out on cadaver animal bones to evaluate the thermal effect of inserting K-wires with a pneumatic hammer as compared to drilling. The mean maximum bone temperature 0.5 mm from the K-wires was 34 (22-72) degrees C using the hammer and 54 (19-100) degrees C for drilling, 1.0 mm from the K-wire the mean maximum temperature was
Soren Toksvig-Larsen
exaly +3 more sources
Laboratory tests were carried out on cadaver animal bones to evaluate the thermal effect of inserting K-wires with a pneumatic hammer as compared to drilling. The mean maximum bone temperature 0.5 mm from the K-wires was 34 (22-72) degrees C using the hammer and 54 (19-100) degrees C for drilling, 1.0 mm from the K-wire the mean maximum temperature was
Soren Toksvig-Larsen
exaly +3 more sources
Effect of Cerclage Wires on Periosteal Bone in Growing Dogs
Veterinary Surgery, 1987Three diameters of wire were placed circumferentialiy around the femora of six 22 week old puppies. The wires were placed over the periosteum on one limb and under the periosteum on the other limb. The effect of the wires on actively growing bone was evaluated 3 and 8 weeks after placement. Diffuse growth of periosteal new bone occurred in immature dog
exaly +3 more sources