Proximal Humerus Internal Locking System (PHILOS) Plating Versus External Fixation Using Kirschner Wires (K-Wires) With Frames for Proximal Humerus Fractures: A Prospective Comparative Study. [PDF]
Kumar P +4 more
europepmc +1 more source
Abstract Purpose To investigate the changes in tibiofemoral contact mechanics following an infra‐tubercle slope‐modifying osteotomy. Methods An infra‐tubercle slope‐modifying osteotomy was performed on eight fresh‐frozen cadaveric knees and fixed with an external fixator, which allowed for accurate slope adjustments from 15° to 0° in 5° increments. The
Christian Peez +8 more
wiley +1 more source
Preserved Thumb Function After First MCP Joint Arthrodesis with Pins for Degenerative Arthritis Secondary to Chronic Dorsal Thumb Dislocation in Resource-Limited Settings - A Case Report. [PDF]
Belay TD, Ahmed AM, Anyanwu EG.
europepmc +1 more source
Abstract Purpose The objective was to measure effects of joint line obliquity (JLO) on meniscus posterior root tension, tibiofemoral subluxation and contact pressures. It was hypothesised that a medial JLO would increase medial meniscal (MM) root tension, medial tibiofemoral subluxation and medial compartment contact pressure, and vice versa for ...
Shuntaro Nejima +5 more
wiley +1 more source
Abstract Increased posterior tibial slope (PTS) is a known risk factor for anterior cruciate ligament (ACL) deficiency and graft failure after ACL reconstruction (ACLR). Although many studies investigated different aspects related to the PTS, there is still a lack of comprehensive recommendations and practical guidelines, especially with regard to ...
Philipp Mayer +13 more
wiley +1 more source
Non-union rates and complications after elective interphalangeal joint arthrodesis of the hand: a cohort study of 366 arthrodeses in 289 patients. [PDF]
Lindberg K +5 more
europepmc +1 more source
Patient Experience of Undergoing MRI With a New Active Transcutaneous Bone‐Anchored Hearing Implant
Active transcutaneous bone‐anchored hearing implants belong to a class of devices that may pose challenges in magnetic resonance imaging (MRI) settings. In this prospective study, all MRI scans in patients (n = 15) with the Sentio Ti implant were completed without complications, and patients reported generally positive experiences with low levels of ...
Carine Hajema +10 more
wiley +1 more source
Multiple Intramedullary and Skewer Pin Fixation for Complex Humeral and Femoral Fractures in Cats and Small-Breed Dogs. [PDF]
Öztürk Y.
europepmc +1 more source
Hydrogen‐enhanced SCC of WAAM Inconel 625 in 3.5 wt.% NaCl solution. Hydrogen charging reduces passive film stability (lower corrosion potential) and promotes pitting at Laves phase/matrix interfaces. Stress corrosion cracks propagate along Laves‐rich regions, leading to quasi‐cleavage brittle fracture.
Xu Zhang +5 more
wiley +1 more source
Delta external fixation as a suitable option for definitive fixation of osteoporotic pilon fractures in biomechanics: a finite element analysis. [PDF]
Chen P +11 more
europepmc +1 more source

