Results 81 to 90 of about 4,192,467 (303)
Selective elimination of quiescent cancer cells by dequalinium chloride via ROS‐mediated ferroptosis
Dequalinium chloride (DQ) selectively eliminates quiescent cancer cells (QCCs) by amplifying mitochondrial ROS. QCCs exhibit elevated basal ROS and limited redox‐buffering capacity, making them vulnerable to further ROS increases. DQ‐induced ROS exceeds the tolerance threshold, triggering lipid peroxidation and ferroptosis, whereas proliferating cells ...
Kotaro Miyamoto +14 more
wiley +1 more source
Enhancing Passive Microwave Brightness Temperature Using Dual-Attention SRGAN
This study presents a dual-attention super-resolution generative adversarial network (DA-SRGAN) framework to enhance the spatial resolution of passive microwave (PMW) brightness temperature (TB) data from 12.5/25 km to 3.125/6.25 km.
Junhwa Chi, Jinku Park, Hyun-Cheol Kim
doaj +1 more source
Brightness temperature constraints from interferometric visibilities
Context. The brightness temperature is an effective parameter that describes the physical properties of emitting material in astrophysical objects. It is commonly determined by imaging and modeling the structure of the emitting region and estimating its ...
Andrei Lobanov, Lobanov, A.
core +1 more source
Geometry‐driven thermal behavior in wire‐arc additive manufacturing (WAAM) influences microstructural evolution during nonequilibrium solidification of a chemically complex Fe–Cr–Nb–W–Mo–C nanocomposite system. By comparing different deposits configurations, distinct entropy–cooling rate correlations, segregation, and carbide evolution are revealed ...
Blanca Palacios +5 more
wiley +1 more source
A Measurement of the Sky Brightness Temperature at 408 MHz
The absolute value of the background brightness temperature has been measured at a radiofrequency of 408 MHz. Observations were made with a large pyramidal "standard gain" horn aerial and the aerial temperatures were compared direct with the temperature ...
RM Price
core +1 more source
Temperature retrieval algorithm for brain temperature monitoring using microwave brightness temperatures [PDF]
A solution to the inverse problem of retrieving temperature from a set of microwave brightness temperatures together with a priori information regarding weighting functions and heat transfer within the infant head is introduced.
Mizushina, S. +3 more
core +1 more source
Thermomechanical fatigue tests of laser beam powder bed fusion (PBF‐LB) Inconel 718 show that the additively manufactured material reaches almost the lifetimes of conventionally‐rolled material under no‐dwell conditions. Introducing dwell times at the maximum temperature markedly reduces the lifetimes due to pronounced grain boundary sliding associated
Stefan Guth +6 more
wiley +1 more source
Copper‐based composites enhanced with carbon feature convenient mechanical properties and favorable electric conductivity. Processing via deformation and thermomechanical treatments can introduce advantageous microstructures further enhancing their performance. Herein, copper–graphene powder‐based composites are directly consolidated via rotary swaging
Radim Kocich +3 more
wiley +1 more source
The brightness temperature of Mercury at 150 and 240 GHz
During the Italian Antarctic Expedition 2004/2005 we observed Mercury at 150 and 240 GHz. The observations have been carried out by means of the 2.6m OASI telescope.
L. Pizzo +5 more
core +2 more sources
Modeling of brightness temperature in biological tissue
Abstract Microwave radiothermometry is a passive and non-invasive technique which is used to measure the depth temperature of biological tissue. The method of microwave radio thermometry is based on measuring the intensity of the own electromagnetic radiation of the internal tissues of the patient in the ultra-high frequency range.
M Polyakov, V Levshinskii, A Khoperskov
openaire +1 more source

