Fracture of the Femoral Broach Locking Mechanism and Surgical Technique to Retrieve the Broach [PDF]
The current case series reports on 4 cases of intraoperative fracture of the femoral broach locking mechanism during total hip arthroplasty and subsequent entrapment of the broach.
Peter P. Hsiue, MD +5 more
doaj +2 more sources
Novel Strategy for Incarcerated Broken Broach Retrieval in Total Hip Arthroplasty [PDF]
Introduction: The goal of femoral component positioning in cementless total hip arthroplasty (THA) is accurate restoration of joint biomechanics and a press fit between the implant and the endosteal surface of the proximal femur.
Sanjay Agarwala +2 more
doaj +2 more sources
STRENGTH ANALYSIS METHODS OF CIRCULAR PULL BROACH COGS [PDF]
A very big importance in a pull broach designing is represented by its mechanic computation, which trots out the pull broach resistance on various blank tooling, pull broach productivity and also the loadings which is subdued to and the stresses that ...
Cosmin MIRIŢOIU
doaj +2 more sources
Optimal Bone Preparation for Triple-Tapered Stems: Does the Sagittal Taper Affect Optimal Femoral Sizing? [PDF]
Background: Conventional single-tapered, total hip arthroplasty stems achieve fixation namely through coronal, metaphyseal fit. Triple taper stems have a sagittal taper to optimize fixation in the antero-posterior (AP) plane as well; however, limited ...
Jeff Shi, MD +5 more
doaj +2 more sources
Quasi-static mechanical evaluation of canine cementless total hip replacement broaches: effect of tooth design on broach and stem insertion [PDF]
Background Biomedtrix BFX® cementless total hip replacement (THR) requires the use of femoral broaches to prepare a press-fit envelope within the femur for subsequent stem insertion.
Zachary T. Lawson +5 more
doaj +2 more sources
Short- and Mid-term Radiographic Outcomes of Ream-then-broaching Metaphyseal Cones During Revision Total Knee Arthroplasty [PDF]
Background: The purpose of this study is to assess the short- and mid-term radiographic outcomes of a ream-then-broach metaphyseal cone design for revision total knee arthroplasty (rTKA).
Aria Darbandi, MD +8 more
doaj +2 more sources
TESTING DURABILITY OF A BROACH
In integrated manufacturing systems, a very important issue is the problem of ensuring the reliability of cutting tools, in particular high-speed steel broaches.
Magdalena Bucior +2 more
doaj +1 more source
Simulation and research of cylindrical broach structures stress-strain state in solidworks system [PDF]
The authors considered a methodology for the automated design of cylindrical broach structures consisting of the following stages: forming a 3D-parametric geometrical broach image, assessing a broach structure stress-strain state during operation.
Lukina Svetlana +2 more
doaj +1 more source
CONSTRUCTION AND TECHNOLOGICAL ANALYSIS OF THE BROACH BLADE SHAPE USING THE FINITE ELEMENT METHOD [PDF]
The paper presents results of numerical FEM analyses of the process of broaching the groove using the Explicit module of the ABAQUS program. The impact of the blade geometry was presented and of the selected technological parameters of processing when ...
Stanisław BŁAWUCKI, Kazimierz ZALESKI
doaj +1 more source
Background: A not infrequent complication encountered with the direct anterior approach is perioperative fracture. The purpose of this study was to compare the incidence of perioperative fractures using a hybrid rasp-impaction broach vs an impaction ...
James M. Hartford, MD +2 more
doaj +1 more source