Results 11 to 20 of about 3,439,196 (128)

Pattern Electroretinogram Parameters Are Associated with Optic Nerve Morphology in Preperimetric Glaucoma after Adjusting for Disc Area

open access: yesJournal of Ophthalmology, 2021
Purpose. We examined the relationships between pattern electroretinogram and optical coherence tomography derived optic nerve head measurements, after controlling for disc area. Methods.
Andrew Tirsi   +8 more
doaj   +3 more sources

Effect of Conventional Cataract Surgery and Femtosecond Laser-Assisted Cataract Surgery on Bruch’s Membrane Opening-Minimum Rim Width, Retinal Nerve Fiber Layer, and Macular Thickness

open access: yesJournal of Ophthalmology, 2023
Purpose. To evaluate the effect of conventional cataract surgery (CCS) and femtosecond laser-assisted cataract surgery (FLACS) on Bruch’s membrane opening-minimum rim width (BMO-MRW), peripapillary retinal nerve fiber layer thickness (RNFL), and macular ...
Josefina Reñones   +4 more
doaj   +3 more sources

Factors Associated with Increased Neuroretinal Rim Thickness Measured Based on Bruch’s Membrane Opening-Minimum Rim Width after Trabeculectomy [PDF]

open access: yesJournal of Clinical Medicine, 2021
Purpose: To investigate the factors associated with an increase in the neuroretinal rim (NRR) thickness measured based on Bruch’s membrane opening-minimum rim width (BMO-MRW) after trabeculectomy in patients with primary open-angle glaucoma (POAG ...
Park DY, Cha SC.
exaly   +3 more sources

New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch’s Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs

open access: yesJournal of Ophthalmology, 2019
Purpose. To compare the new spectral-domain optical coherence tomography (SD-OCT) algorithm for measuring circumpapillary retinal nerve fiber layer (RNFL) thickness centered on Bruch’s membrane opening (BMO), RNFLBMO1, with the conventional ...
Serife Bayraktar   +4 more
doaj   +3 more sources

Repeatability of Spectral Domain Optical Coherence Tomography Measurements of Bruch’s Membrane Opening-Minimum Rim Width in Epiretinal Membrane Patients with Peripapillary Involvement [PDF]

open access: yesJournal of Clinical Medicine, 2021
The Bruch’s membrane opening-minimum rim width (BMO-MRW) is a recently introduced parameter of the neuroretinal rim. We analyzed the repeatability of spectral-domain optical coherence tomography (SD-OCT) measurements of BMO-MRW in epiretinal membrane ...
Ki Yup Nam, Yong Seop Han, Woo Hyuk Lee
exaly   +3 more sources

Rate of Change in Bruch’s Membrane Opening-Minimum Rim Width and Peripapillary RNFL in Early Normal Tension Glaucoma [PDF]

open access: yesJournal of Clinical Medicine, 2020
Background: to investigate the rate of change (ROC) of Bruch’s membrane opening minimum rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (RNFL) thickness in early normal tension glaucoma (NTG) patients.
Hyun-Kyung Cho   +2 more
exaly   +3 more sources

Characteristics of Patients Showing Discrepancy Between Bruch’s Membrane Opening-Minimum Rim Width and Peripapillary Retinal Nerve Fiber Layer Thickness [PDF]

open access: yesJournal of Clinical Medicine, 2019
Background: To investigate clinical characteristics of patients showing discrepancy between Bruch’s membrane opening minimum rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (RNFL) thickness.
Hyun-Kyung Cho   +2 more
exaly   +3 more sources

Bruch’s Membrane Opening Minimum Rim Width Measurement with SD-OCT: A Method to Correct for the Opening Size of Bruch’s Membrane [PDF]

open access: yesJournal of Ophthalmology, 2017
A precise evaluation of the retinal nerve fiber layer thickness (RNFLT) is key for diagnosing and monitoring glaucoma. The Bruch’s membrane opening minimum rim width (BMO-MRW) has been proposed as a reproducible assessment of the optic nerve. The BMO-MRW
Robert Kromer, Martin Stephan Spitzer
doaj   +2 more sources

Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness in a Brazilian population of healthy subjects.

open access: yesPLoS ONE, 2018
OBJECTIVE:To determine Bruch's membrane opening (BMO) minimum rim width (MRW) and peripapillary retinal nerve fiber layer thickness (RNFLT) measurements, acquired with optical coherence tomography (OCT) in healthy Brazilian individuals self-reported as ...
Camila S Zangalli   +6 more
doaj   +2 more sources

Implantation of a posterior chamber phakic intraocular lens on Bruch’s membrane opening-minimum rim width, retinal nerve fiber layer, and macular thickness [PDF]

open access: yesInternational Journal of Ophthalmology
AIM: To assess whether the implantation of a posterior chamber phakic intraocular lens produces changes in optical coherence tomography (OCT) measurements of macular thickness (MT) and two parameters that define the structure of the optic nerve, the ...
Josefina Reñones   +6 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy