Results 1 to 10 of about 670,679 (301)

“Bubble Bunch” phenomenon in operation of a bubble column

open access: yesOpen Chemistry, 2009
Abstract While studying the operation of a rectangular bubble column in laboratory scale, it was observed that under certain circumstances tiny bubbles attach to larger bubbles without causing them to coalesce. In other words, bubbles with large diameters (d > 5 mm) swept tiny bubbles (d
Bastani Dariush   +2 more
openaire   +2 more sources

Bubble properties of heterogeneous bubbly flows in a square bubble column [PDF]

open access: yesAIP Conference Proceedings, 2010
The present work focuses on the measurements of bubble properties in heterogeneous bubbly flows in a square bubble column. A four-point optical fibre probe was used for this purpose. The accuracy and intrusive effect of the optical probe was investigated first.
W. Bai   +7 more
openaire   +2 more sources

The Latest Frontiers of Bubble Columns and Slurry Bubble Columns. Gas Holdup and Bubble Behaviour in a Pressurized Bubble Column.

open access: yesKAGAKU KOGAKU RONBUNSHU, 2001
気泡塔のガスホールドアップに対する圧力の影響をガス分散器として用いた単一ノズルの内径およびガスの種類をN2とCO2に変化させて実験的に検討した.単一ノズルの内径が4.0mmの場合にはガスホールドアップに対する圧力の影響はガスの種類によらずほとんど認められなかった.単一ノズルの内径が1.4mmでN2を用いた場合には,ガスホールドアップは圧力とともに増加した.単一ノズルの内径が1.4mmでCO2を用いた場合には,ガスホールドアップは0.6MPa付近まで圧力と共に増加した,さらに圧力が上昇するとガスホールドアップは減少した.塔壁面での気泡の写真撮影および塔中心部での気泡頻度の測定を行い,前述の現象の原因について実験的に検討した.
Ishiyama, Hiroshi   +3 more
openaire   +1 more source

The Latest Frontiers of Bubble Columns and Slurry Bubble Columns. Effect of Oil Dispersion on Flow Characteristics in Bubble Column.

open access: yesKAGAKU KOGAKU RONBUNSHU, 2001
気泡塔の流動特性に及ぼす油分分散の影響について実験的に検討した.油分の種類および濃度を変えて水道水に分散させ,気泡の流動状態および油分分散を観察し,油滴径分布・ガスホールドアップおよび液相基準物質移動容量係数を測定した.液中に安定に分散する小さな油滴が流動特性に影響する.ガスホールドアップは水道水の場合より高く,容量係数は低くなる.これらのことより,油分分散系では物質移動係数が低下すると推察される.
Bando, Yoshiyuki   +5 more
openaire   +1 more source

Unified modeling of bubbly flows in pipes, bubble columns, and airlift columns

open access: yesChemical Engineering Science, 2017
Abstract Multiphase CFD simulation is a valuable tool in process engineering which is particularly useful to study new reactor concepts and their scale-up from laboratory to production scale. Simulations of bubbly flows up to industrial dimensions are feasible within the Eulerian two-fluid framework of interpenetrating continua.
Rzehak, R.   +4 more
openaire   +1 more source

Effect of pressure on gas holdup in a bubble column and a slurry bubble column.

open access: yesJOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1991
The bubble column is a stainless steel tube with inner diameter of 45 mn and has a cone-shaped bottom. The height of the multiphase contacting section was varied from 0.83 to 1.40 m. The gas was sparged into the column through a single nozzle with inner diameter of 0.59, 1.0, 2.0 or 3.0 mm and with outer diameter of 14 mm.
Kojima, Hiromitsu   +2 more
openaire   +2 more sources

bubble column

open access: yes, 2014
Citation: 'bubble column' in the IUPAC Compendium of Chemical Terminology, 3rd ed.; International Union of Pure and Applied Chemistry; 2006. Online version 3.0.1, 2019. 10.1351/goldbook.B00750 • License: The IUPAC Gold Book is licensed under Creative Commons Attribution-ShareAlike CC BY-SA 4.0 International for individual terms. Requests for commercial
openaire   +1 more source

The Latest Frontiers of Bubble Columns and Slurry Bubble Columns. Flow Characteristics in Bubble Column with Draft Tube and Performance Improvement.

open access: yesKAGAKU KOGAKU RONBUNSHU, 2001
ドラフトチューブ付気泡塔の流動特性について装置因子の観点から,とくにドラフトチューブ長さ,上下の隙間の長さ等の影響を検討した.液混合時間に及ぼす塔のアスペクト比(塔高/塔径)の影響および液循環流量に及ぼすドラフトチューブ上端から通気時の液面までの距離の影響を明確にした.また,気液の循環流量の関係を示した.次に,ドラフトチューブを改良した研究を紹介した.多孔ドラフトチューブを挿入した気泡塔では,特異な流動挙動により,気液物質移動および液混合性能が大きく改善されることを示した.また,充填物・向流式気泡塔と多孔ドラフトチューブとの組合せ等の一連の研究および高粘性液における性能改善や排水処理への応用研究の結果を示し,考察を加えた.さらに ...
openaire   +1 more source

Bubble Properties in Bubble Columns with Electrolyte Solutions

open access: yesKorean Chemical Engineering Research, 2016
− Bubble properties such as size (chord length) and rising velocity were investigated in a bubble column with electrolyte solutions, of which diameter was 0.152m and 2.5m in height, respectively. The size and rising velocity of bubbles were measured by using the dual electrical resistivity probe method.
D.J. Yoo   +4 more
openaire   +2 more sources

Properties of bubble swarm in a slurry bubble column.

open access: yesJOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1987
The effects of solid concentration and liquid viscosity on bubble properties such as bubble size and bubble rising velocity were measured with a dual-electroresistivity probe in a slurry bubble column of 0.15m diameter. The behavior of volume-surface mean bubble diameter, dvs, was analyzed.
FUKUMA, MIKI   +2 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy