Results 211 to 220 of about 90,746 (265)

A bibliometric analysis of photobiomodulation therapy for the prevention and treatment of chemotherapy- and radiotherapy-induced oral mucositis. [PDF]

open access: yesFront Oral Health
Kurmanalina M   +6 more
europepmc   +1 more source

Bubble-size distributions in foams

Advances in Colloid and Interface Science, 1992
Abstract Bubble-size distributions in foams can be used to study foam properties and to distinguish between the physical processes that contribute to the breakdown of the foam. These processes are drainage, coalescence and disproportionation. A new Foam Analyzer was developed to measure various foam characteristics like the rate of drainage, the rate
Bisperink, C.G.J.   +2 more
openaire   +2 more sources

Bubble size estimation in a bubble swarm

Journal of Colloid and Interface Science, 1988
Abstract The hindered settling equations of J. H. Masliyah (Chem. Eng. Sci.34, 1166 (1979)) have been adapted to predict mean bubble size in bubble swarms. The measurements required are superficial liquid and gas rates, and gas holdup. Predicted and measured (by photography) bubble sizes agree within 15% over the tested range 0.5–1.5 mm.
J.B Yianatos   +3 more
openaire   +1 more source

Bubble size distribution in bubble columns

The Canadian Journal of Chemical Engineering, 1990
AbstractThe bubble size distributions are measured for the air‐water system as a function of air velocity at room temperature in two bubble columns. High speed cinephotography and fiber optic probe techniques are used to measure the bubble size. Our limited measurements suggest that the bubble size may be independent of gas velocity in the range 3.6 to
A. C. Saxena, N. S. Rao, S. C. Saxena
openaire   +1 more source

Bubble sizing with a high spatial resolution

IEEE 1988 Ultrasonics Symposium Proceedings., 1990
The authors propose a technique that allows them to size bubbles with the same accuracy as with the double-frequency method and to locate them with the same range resolution as with the pulsed Doppler velocimeter. They demonstrate that the signal scattered by the bubble insonified by a high-frequency pulsed ultrasonic field and a low-frequency pumping ...
D, Cathignol   +3 more
openaire   +2 more sources

Prediction of the bubble-hole size of a cap bubble in a bubble swarm

Chemical Engineering Science, 1997
Abstract A phenomenological, semi-theoretical model is proposed for predicting the size or thickness of the bubble-depleted region, or ‘bubble hole’, in the frontal vicinity of a larg cap bubble rising through a swarm of otherwise uniformly dispersed small bubbles.
Katsumi Tsuchiya, Kazutomo Ohsaki
openaire   +1 more source

Factor Affecting Bubble Creation and Bubble Size

Volume 1: Advances in Aerospace Technology; Energy Water Nexus; Globalization of Engineering; Posters, 2011
This paper presents the factors affecting air bubble size when air is injected through a perforated membrane into a water pool. Critical factors that govern the size of air bubbles are the air pressure and the flow rate as well as the hole size of the diffuser membrane. In order to have a better understanding of how bubble size can be affected and what
Ammar A. T. Alkhalidi, Ryo S. Amano
openaire   +1 more source

Optical monitoring of bubble size and shape in a pulsating bubble surfactometer

Journal of Applied Physiology, 2005
The pulsating bubble surfactometer (PBS) is often used for in vitro characterization of exogenous lung surfactant replacements and lung surfactant components. However, the commercially available PBS is not able to dynamically track bubble size and shape.
Shannon L, Seurynck   +8 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy