Impact of Cable Configuration on the Voltage Induced in Cable Screen during Work with One-Sidedly Ungrounded Cable Screen [PDF]
In the latest research, it has been proven that from the point of view of losses in a cable distribution line, the most advantageous operation is to work with two or one phase of metallic cable screen ungrounded.
Aleksandra Schött-Szymczak +1 more
doaj +6 more sources
Analysis of Cable Screen Currents for Diagnostics Purposes [PDF]
This paper presents current flow in cable screens and a cable screen earthing system. Moreover, the paper presents the methodology for the detection of problems in cable screens, such as open phase in a cable screen and high contact resistance of a cable
Krzysztof Lowczowski +2 more
doaj +6 more sources
Monitoring of MV Cable Screens, Cable Joints and Earthing Systems Using Cable Screen Current Measurements [PDF]
The paper presents the possibility of using cable screen earthing current measurements for MV, single-core cable line monitoring. Cable screen earthing current measurement allows the condition of cable screen connections, degradation of earthing systems,
Krzysztof Lowczowski +4 more
doaj +4 more sources
Analysis of Overvoltages Appearing in One-Sidedly Ungrounded MV Power Cable Screen [PDF]
Changing the connection type of a medium voltage (MV) cable screen is linked to a decrease in power loss, although it may also lead to the generation of overvoltage in a metallic cable screen, which is hazardous for proper cable line work. In this paper,
Aleksandra Schött-Szymczak +1 more
doaj +4 more sources
Experiences with cable faults located at metallic screen connections [PDF]
Overheating of metallic ground screen connections at accessories of single core cables are the root cause of severe insulation failures in the distribution network. The overheating is due to a high transition resistance of the connections combined with high induced currents in the ground screens during operation.
H. L. Halvorson +3 more
exaly +4 more sources
Experimental Study on Tele-Manipulation Assistance Technique Using a Touch Screen for Underwater Cable Maintenance Tasks [PDF]
In underwater environments restricted from human access, many intervention tasks are performed by using robotic systems like underwater manipulators.
Gun Rae Cho +5 more
doaj +4 more sources
Novel Earth Fault Protection Algorithm Based on MV Cable Screen Zero Sequence Current Filter [PDF]
This paper presents novel zero sequence current filter and earth fault protection relay, which utilize cable screens earthing current in protection algorithm.
Krzysztof Lowczowski +4 more
doaj +4 more sources
Utilization of Cable Screen Earthing Current for Detection and Location of Earth Faults in Medium Voltage Networks [PDF]
The paper presents issues related with detection and location of earth faults in medium voltage (MV) networks. Attention is paid on cable and cable-overhead lines. The criterion value – cable screen earthing current is presented.
Krzysztof Łowczowski +3 more
doaj +2 more sources
Effects of Multiple Semiconducting Screens on Line Parameters and Wave Properties of Underground Cable [PDF]
Along with the geometric and electromagnetic properties, incorporation of multiple semiconducting screens in an underground (UG) power cable influences the primary line parameters as well as wave properties of the cable.
Swarnankur Ghosh +2 more
doaj +2 more sources
This paper presents the final development of an expert system utilizing a measurement of cable screen earthing transient current. The developed system allows for identification and location of earth fault in underground cable and mixed lines (underground
Krzysztof Łowczowski, Bartosz Olejnik