Results 21 to 30 of about 1,630,900 (354)
Effect of cosmic rays irradiation on the phase change characteristics of an on-orbit fixed point
Using the phase change characteristics of fixed points to trace the temperature of a spaceborne calibration blackbody is an important technical means to carry out the high-precision on-orbit calibration of thermal infrared remote sensors.
Yiru Chen +8 more
doaj +1 more source
In-flight performance and calibration of the Infrared Array Camera (IRAC) for the Spitzer Space Telescope [PDF]
The Infrared Array Camera (IRAC) is one of three focal plane instruments on board the Spitzer Space Telescope. IRAC is a four-channel camera that obtains simultaneous broad-band images at 3.6, 4.5, 5.8, and 8.0 μm in two nearly adjacent fields of view ...
G. Fazio +64 more
semanticscholar +1 more source
Selection and Treatment of Data for Radiocarbon Calibration: An Update to the International Calibration (IntCal) Criteria [PDF]
High-quality data from appropriate archives are needed for the continuing improvement of radiocarbon calibration curves. We discuss here the basic assumptions behind 14C dating that necessitate calibration and the relative strengths and weaknesses of ...
Beck, J. Warren, +112 more
core +1 more source
Preliminary Selection and Characterization of Pseudo-Invariant Calibration Sites in Northwest China
Pseudo-invariant calibration sites (PICS) have been used for the radiometric calibration and stability monitoring of satellite optical sensors. Several stable PICS, such as those in the Sahara Desert in North Africa, were selected for the vicarious ...
Xiuqing Hu +9 more
doaj +1 more source
Save the "THRU" in the A.N.A. calibration [PDF]
The conventional network analyzer (NWA) two-port calibration procedures require a standard thru line to be connected between the ports. Unfortunately in many applications, for example when measuring MMIC or on-wafer devices with not aligned ports, a ...
FERRERO, ANDREA PIERENRICO +2 more
core +1 more source
Calibration of Pre-trained Transformers [PDF]
Pre-trained Transformers are now ubiquitous in natural language processing, but despite their high end-task performance, little is known empirically about whether they are calibrated.
Shrey Desai, Greg Durrett
semanticscholar +1 more source
SHCal20 Southern Hemisphere Calibration, 0–55,000 Years cal BP
Early researchers of radiocarbon levels in Southern Hemisphere tree rings identified a variable North-South hemispheric offset, necessitating construction of a separate radiocarbon calibration curve for the South.
A. Hogg +14 more
semanticscholar +1 more source
A simple NWA calibration algorithm based on a transfer standard [PDF]
A new two-port network analyzer (NWA) calibration technique is here presented. It uses a single two-port transfer standard plus a known reflectance to perform the calibration process.
A. Ferrero +6 more
core +1 more source
16 pages, 9 figures, accepted at ECML PKDD ...
Gregory Scafarto +2 more
openaire +2 more sources
Study of the Radiochromic Film for High Dose Measurement in Radiation Processing
To establish the radiochromic film dosimeter for high dose level measurement during radiation processing, By corresponding formula and its preparation process research, batches of radiochromic film dosimeters were prepared using nylon as substrate and ...
CHEN Yi-zhen +3 more
doaj +1 more source