Results 1 to 10 of about 719 (107)

Outcomes of Headed and Headless Cannulated Screws Fixation in Nondisplaced Femoral Neck Fracture [PDF]

open access: yesGeriatric Orthopaedic Surgery & Rehabilitation
Background The incidence of femoral neck fracture is increasing as society ages. Different types of cannulated screws can be used for internal fixation of femoral neck fractures, but no screw selection protocol has been determined to reduce the risk of ...
Ko-Ta Chen MD   +3 more
doaj   +3 more sources

Evaluation of Cannulated Compression Headless Screw (CCHS) as an alternative implant in comparison to standard S1-S2 screw fixation of the posterior pelvis ring: a biomechanical study [PDF]

open access: yesBMC Musculoskeletal Disorders, 2023
Background/Purpose Posterior pelvis ring injuries represent typical high-energy trauma injuries in young adults. Joint stabilization with two cannulated sacroiliac (SI) screws at the level of sacral vertebrae S1 and S2 is a well-established procedure ...
Till Berk   +8 more
doaj   +2 more sources

Posterior Arthroscopic Talar Body Nonunion Repair With Subtalar Arthrodesis. [PDF]

open access: yesArthrosc Tech
Abstract Talus fractures are a rare and challenging problem for the orthopaedic surgeon. They often present following high‐speed injury mechanisms in patients with polytraumatic injuries. Diagnosis and treatment of these fractures may be delayed, at times leading to talus nonunion or malunion.
Ardavanis KS   +3 more
europepmc   +2 more sources

A biomechanical comparison of closed-reduction osteosynthesis techniques for fractures of the ulnar styloid [PDF]

open access: yesJournal of Orthopaedic Surgery and Research
Background Ulnar styloid fractures (USF) are frequently underestimated and can contribute to clinically relevant wrist instability and impaired functional outcomes. Several osteosynthesis techniques are available for the treatment of unstable USF.
Jonas Eck   +7 more
doaj   +2 more sources

Rotational Stability in a Feline Sacroiliac Luxation Model: Biomechanical Comparison of Cannulated Compression Headless Screws and Cortical Screws Applied in Positional or Lag Fashion [PDF]

open access: yesAnimals
The purpose of this study was to compare the rotational stability of cannulated compression headless screws (CCHSs) with cortical positional and lag screws in a simulated cadaveric feline sacroiliac luxation (SIL) model.
Jana Klement   +6 more
doaj   +2 more sources

Minimally Invasive Arthroscopic Fixation of Scaphoid Nonunion in Adolescents Shows High Union Rates, Improved Function, and Low Morbidity. [PDF]

open access: yesArthrosc Sports Med Rehabil
Purpose To evaluate the clinical, radiographic, and functional outcomes of arthroscopic treatment of scaphoid nonunion in adolescents, using cancellous bone grafting combined with headless compression screw fixation. Methods This retrospective study included adolescent patients treated between 2015 and 2022 with arthroscopically assisted bone grafting ...
Kaempf R   +5 more
europepmc   +2 more sources

Interfragmentary compression in a feline sacroiliac luxation model: biomechanical comparison of cannulated compression headless screws and cortical screws applied in positional or lag fashion [PDF]

open access: yesBMC Veterinary Research
Background The purpose of this study was to compare the efficacy of cannulated compression headless screws (CCHS) with cortical positional and lag screws in generating interfragmentary compression in a simulated feline sacroiliac luxation fracture (SILF)
Laura Wachsmuth   +6 more
doaj   +2 more sources

Tips and Tricks for Hardware Removal and Allograft Fixation After a Failed Latarjet Procedure. [PDF]

open access: yesArthrosc Tech
Abstract Although relatively rare, recurrent anterior shoulder instability requiring revision surgery after a failed Latarjet procedure can result in complications such as graft malposition, graft osteolysis, broken hardware and/or infection. Revision surgery after a failed Latarjet is a challenge due to a combination of technical factors such as ...
DeFoor MT   +7 more
europepmc   +2 more sources

Does fully-threaded Headless Compression Screw provide a length-stable fixation in undisplaced femoral neck fractures?

open access: yesAsian Journal of Surgery, 2019
Summary: Objective: Femoral neck shortening is a common complication after surgical treatment for intracapsular femoral neck fractures. This study investigated whether fully-threaded Headless Compression Screw (FTHCS) can be a more length-stable implant
Ming-Hung Chiang   +4 more
doaj   +3 more sources

A rare traumatic triad: Open bicondylar non-conjoint Hoffa fracture with partial tibial tubercle and medial epicondyle avulsions – A case report and biomechanical analysis [PDF]

open access: yesTrauma Case Reports
Coronal shear fractures of the distal femoral condyles are rare intra-articular injuries, and the simultaneous occurrence of a non-conjoint bicondylar Hoffa fracture with a partial anterior tibial tubercle avulsion and a medial epicondyle avulsion ...
Abdelwahed Soleh   +5 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy