Results 11 to 20 of about 590,483 (139)

Biomechanical Comparison of Self-Compressing Screws and Cortical Screw Inserted with Lag Fashion in Canine Cadaveric Humeral Condylar Fracture Model [PDF]

open access: yesVeterinary Sciences
This study compares the compression force of cortical screws used in lag fashion with partially threaded cannulated screws and fully threaded headless cannulated screws as fixation methods for humeral condylar fractures in dogs.
Jun-sik Cho   +5 more
doaj   +3 more sources

Opposing Flanks vs Parallel Flanks – the Influence of Headless Screw Design on Compression and Pull- Out Resistance

open access: yesFoot & Ankle Orthopaedics, 2023
Category: Basic Sciences/Biologics; Basic Sciences/Biologics Introduction/Purpose: Screws generate and maintain compression against distracting forces when performing osteotomy or fusion surgery.
Rachel Tan   +5 more
doaj   +2 more sources

Antegrade anterior column acetabulum fracture fixation with cannulated compression headless screws-A biomechanical study on standardized osteoporotic artificial bone. [PDF]

open access: yesPLoS ONE
PurposeDue to the increase in life expectancy and high-energy traumas, anterior column acetabular fractures (ACFs) are also increasing. While open reduction and internal fixation (ORIF) is still the standard surgical procedure, minimally invasive ...
Till Berk   +10 more
doaj   +2 more sources

Arthroscopic Technique for Headless Compression Screw Fixation of Large Bony Bankart Fractures in Anterior Shoulder Instability

open access: yesArthroscopy Techniques
A bony Bankart fracture is a common injury pattern in anterior shoulder instability. The fracture fragment size varies and the larger the fragment the more likely recurrent instability will occur.
Alexander J. Hoffer, M.D., M.Sc., F.R.C.S.C.   +2 more
doaj   +2 more sources

Fresh Talus Allograft Preparation for the Treatment of a Large Off-Track Hill-Sachs Lesion. [PDF]

open access: yesArthrosc Tech
Abstract Large off‐track Hill‐Sachs lesions present a significant challenge in the management of recurrent anterior shoulder instability, particularly in young, active patients. Traditional Hill‐Sachs management procedures include remplissage, coracoid transfer and free bone block reconstruction, which all carry associated limitations, including non ...
Nocek MJ   +5 more
europepmc   +2 more sources

Arthroscopic Targeted Screw Placement: A Minimally Invasive Approach for Hindfoot Fractures. [PDF]

open access: yesArthrosc Tech
Abstract Arthroscopic techniques have emerged as a promising alternative to traditional open reduction internal fixation in the treatment of foot and ankle fractures, offering minimally invasive methods to address intra‐articular fractures. These techniques provide direct visualization of the fracture site while preserving the soft tissue envelope and ...
Anand S, Martin KD.
europepmc   +2 more sources

Olecranon stress fracture treated with headless compression screws and bone marrow aspirate concentrate augmentation: a case report and systematic review of the literature [PDF]

open access: yesJSES Reviews, Reports, and Techniques
Background: Several surgical techniques have been described to treat olecranon stress fractures (OSFs), most commonly involving the use of cannulated screws placed perpendicular to the fracture line of the olecranon. However, hardware removal, infection,
Austin Gartner, MD   +3 more
doaj   +2 more sources

Application of headless cannulated compression screws for treatment of Delbet-Colonna II and III femoral neck fractures in children [PDF]

open access: yesFrontiers in Pediatrics
PurposeFemoral neck fractures are clinically rare and are associated with a high risk of complications in children. Traditional internal fixation implants such as Kirschner wires and partial-thread cannulated screws (PTCS) have complications such as ...
Yikun Jiang   +4 more
doaj   +2 more sources

Biomechanical comparison of different internal fixation devices for transversely unstable Mason type II radial head fractures

open access: yesFrontiers in Bioengineering and Biotechnology, 2023
Background: The integrity of the radial head is critical to maintaining elbow joint stability. For radial head fractures requiring surgical treatment, headless compression cannulated screw fixation is a less invasive scheme that has fewer complications ...
Xiang Zhang   +5 more
doaj   +1 more source

Biomechanical Comparison of Double 2.3-mm Headless Cannulated Self-Compression Screws and Single 3.5-mm Cortical Screw in Lag Fashion in a Canine Sacroiliac Luxation Model: A Small Dog Cadaveric Study [PDF]

open access: yes, 2023
OBJECTIVE  The aim of this study was to evaluate the feasibility of safe positioning of double 2.3-mm headless cannulated self-compression screws (HCS) in a small dog cadaveric sacroiliac luxation model and to compare the static rotational ...
Haebeom Lee   +11 more
core   +2 more sources

Home - About - Disclaimer - Privacy