Results 61 to 70 of about 590,483 (139)

Does protruding headless cannulated screw reduce fixation stability in tension band wiring technique for patella fractures? a biomechanical study

open access: yes
Background The selection of an implant is a critical factor in the surgical treatment of patella fractures due to the riskof various complications, such as non-union, implant failure, and irritation.
Uzun, Bora   +5 more
core   +1 more source

Ordinary Cannulated Compression Screws or Headless Cannulated Compression Screws? A Synthetic Bone Biomechanical Research in the Internal Fixation of Vertical Femoral Neck Fracture

open access: yes, 2018
Purpose. The purpose of this study is to verify whether the headless cannulated compression screw (HCCS) has higher biomechanical stability than the ordinary cannulated compression screw (OCCS) in the treatment of vertical femoral neck fractures ...
Wei Zhang, Jingwen Liu, Baokun Zhang
core   +1 more source

Arthroscopic Debridement and Fixation of Osteochondritis Dissecans Lesions of the Medial Femoral Condyle

open access: yesArthroscopy Techniques, Volume 13, Issue 10, October 2024.
Abstract Unstable osteochondritis dissecans lesions of the medial femoral condyle have classically been treated with open reduction and fixation under direct visualization through an open arthrotomy. Given the value of avoiding open arthrotomies, we present an arthroscopic approach for lesion elevation, debridement, and fixation.
Charles L. Holliday   +6 more
wiley   +1 more source

Biomechanical comparison of variable thread headless compression screw, cannulated screw and suture button application in the surgical treatment of beak type calcaneus fractures [PDF]

open access: yes
Tıp Fakültesi, Ortopedi ve Travmatoloji Ana Bilim DalıAmaç: Kalkaneus kemik modelinde oluşturulan beak tipi kalkaneus kırığının suture button implantının etkinliği ile günümüzde rutin tedavide kullanılan standart kanüllü vida ve değişken yivli başsız ...
Özarı, Özgün
core   +1 more source

Treatment of Moderate Hallux Valgus by Percutaneous, Extra-articular Reverse-l Chevron (PERC) Osteotomy

open access: yesFoot & Ankle Orthopaedics, 2017
Category: Midfoot/Forefoot Introduction/Purpose: The purpose of this study was to report a single surgeon series of consecutive patients with moderate hallux valgus managed with a Percutaneous Extra-articular Reverse-L Chevron (PERC) osteotomy.
Julien Lucas MD, Olivier Laffenetre MD
doaj   +1 more source

Effect of interfragmentary gap on compression force in a headless compression screw used for scaphoid fixation

open access: yes, 2017
We investigated the effect of an interfragmentary gap on the final compression force using the Acutrak 2 Mini headless compression screw (length 26 mm) (Acumed, Hillsboro, OR, USA).
S. C. Tay   +3 more
core   +1 more source

Retrograde headless compression screw fixation of olecranon stress fractures in throwing athletes: a novel technique

open access: yesJSES International
Background: An olecranon stress fracture (OSF) is a rare injury most commonly seen in high-level overhead throwing athletes with no clear consensus on surgical treatment.
Richard M. Michelin, DO   +5 more
doaj   +1 more source

Percutaneous Spondylolysis Repair Using Headless Compression Screws with a Cortical Bone Trajectory: A Technical Description and Case Series

open access: yesSpine Surgery and Related Research
Introduction: Lumbar spondylolysis (LS) is a stress fracture of the pars interarticularis that can occur in adolescents. Both early- and progressive-stage LS can be successfully treated with conservative therapy consisting of activity modification and ...
Naoki Aoyama   +5 more
doaj   +1 more source

Investigation of Start Up Process in Oil Flooded Twin Screw Compressors [PDF]

open access: yes, 2012
Oil injected screw compressors used for air applications and refrigeration are usually installed in simple packages which often do not include oil pump for supply of oil to the bearings and the working chamber.
Stosic, Nikola   +3 more
core   +1 more source

Comparative study of cannulated compression headless screws and anatomical locking compression hook plates for fracture of fifth metatarsal base in athletes and young adults

open access: yesJournal of Orthopaedic Surgery and Research
Background This study aimed to evaluate and compare the clinical effects and complications of cannulated compression headless screws (CHS) and anatomical locking compression hook plates (LCP) for fractures of the displaced fifth metatarsal base zone I in
Yuan Cao   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy