Results 181 to 190 of about 45,603 (231)
Some of the next articles are maybe not open access.

Fixation of tibial pilon fractures with percutaneous cannulated screws

Injury, 2004
Closed reduction and internal fixation with percutaneous cannulated screws was performed on seven patients with closed pilon fractures. The mean follow-up was 30.6 months. They were assessed using a subjective scoring system. The average score was 90.8/100. This method of fixation avoids extensive soft tissue dissection and gives excellent results.
Mujahid Ali, Syed   +1 more
exaly   +3 more sources

Cannulated Screws

Journal of Foot and Ankle Surgery, 2019
Dane K Wukich   +2 more
exaly   +3 more sources

Safety of Computer-assisted Surgery for Cannulated Hip Screws

open access: yesClinical Orthopaedics and Related Research, 2007
Computer-assisted orthopaedic surgery has developed considerably during the past few years. Several manufacturers produce hardware and software for use in trauma surgery. Validation of these systems before clinical application is mandatory to be sure they work accurately and safely. The accuracy of surgical performance is highly correlated with the cut-
Hamelinck, H.K.M   +5 more
openaire   +4 more sources

Technique for Removal of Cannulated Screws

Journal of Orthopaedic Trauma, 2005
Cannulated screws can become incarcerated or stripped during the process of initial open-reduction internal fixation or at the time of hardware removal. In addition, many different sizes and brands of cannulated screws exist, and the appropriate size or type of screwdriver may not be available.
H David, Moehring   +2 more
openaire   +2 more sources

Fixation of an Atlantoaxial Subluxation by Use of Cannulated Screws

open access: yesVeterinary and Comparative Orthopaedics and Traumatology, 1999
An eight month old Rottweiler was presented with signs of a cervical spinal cord lesion. Hypoplasia of the dens and subsequent atlantoaxial (A-A) subluxation was diagnosed by radiography.
A. Shores, M. C. Rochat
exaly   +2 more sources

Cannulated screws for odontoid screw fixation and atlantoaxial transarticular screw fixation

Journal of Neurosurgery, 1995
✓ Cannulated screw systems use thin Kirschner wires (K-wires) that have been drilled into the bone to direct screw trajectories accurately into small bone fragments. Use of the K-wires avoids overdrilling the pilot holes and allows fixation of adjacent bone fragments during screw insertion. Hollow tools and hollow screws are inserted into the bone over
C A, Dickman   +3 more
openaire   +2 more sources

Extraction Strength of Cannulated Cancellous Bone Screws

Journal of Orthopaedic Trauma, 1993
The purpose of this study was to determine whether the alterations in the relative dimensions of thread and core diameter that accompany cannulation of cancellous bone screws affect their holding strength. The screws were inserted in bovine femoral cancellous bone and mounted in the load train of a materials testing system.
T C, Hearn, J, Schatzker, N, Wolfson
openaire   +2 more sources

Cannulated Screw Fixation of Jones Fractures

The American Journal of Sports Medicine, 2004
Background Traditional nonsurgical treatment of Jones fractures has high rates of delayed union, nonunion, and refracture. Internal fixation has become the treatment of choice in athletes and active patients. Purpose The purpose of ...
Keri, Reese   +4 more
openaire   +2 more sources

Lesser digital fusion with a cannulated screw

The Journal of Foot and Ankle Surgery, 2005
A dorsal linear longitudinal approach is used to access both the proximal interphalangeal joint (PIPJ) and distal interphalangeal joint (DIPJ). A transverse tenotomy/capsulotomy to enter the PIPJ and DIPJ is next employed. A planar resection of the opposing PIPJ joint surfaces is performed. The cannulated screw guide wire is driven from the head of the
openaire   +2 more sources

Home - About - Disclaimer - Privacy