Results 51 to 60 of about 45,603 (231)

Stability of Talar Neck Fracture Fixation: A Biomechanical Comparison of 4.0 Cannulated Headed Screws and Conical Headless Screws [PDF]

open access: yes, 2009
Objective: The purpose of this study was to compare the mechanical stability of cannulated conical variable pitch headless (CH) screws to partially threaded 4.0 cannulated (4.0 C) screws for fixation of talar neck fractures.
Mercer, Deana   +5 more
core   +1 more source

The positional consistency between guidewire and cannulated or solid screw in robot-assisted spinal internal fixation surgery

open access: yesJournal of Orthopaedic Surgery and Research
Background This study aimed to investigate the positional consistency between the guidewire and the screw in spinal internal fixation surgery. Methods This study involved 64 patients who underwent robot-assisted thoracic or lumbar pedicle screw fixation ...
Jingwei Zhao   +6 more
doaj   +1 more source

Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: a finite element analysis

open access: yesBMC Musculoskeletal Disorders, 2020
Background The treatment of vertical femoral neck fractures (vFNFs) in young patients remains challenging, with a high complication rate by using traditional techniques.
Shi Zhan   +8 more
doaj   +1 more source

Calcaneal reticular plate with cannulated screws fixation for comminuted Hoffa fracture: A case report

open access: yesTrauma Case Reports, 2022
Hoffa fracture is a general term for single condylar or double condylar coronal fractures of the distal femur. It is a rare intra-articular fracture. At present, there is no specific fixation method for such fractures. The traditional method to fix Hoffa
Xuan Pei   +4 more
doaj   +1 more source

Cannulated Screw Fixation For Femoral Neck Fractures : A 5-year Experience In A Single Institution [PDF]

open access: yes, 2014
Cannulated screw fixation is a widely accepted surgical method for management of fractures of the neck of femur especially in patients with poor premorbid conditions, minimally displaced fractures and those from a younger age group.
Khoo CCH, Amber Haseeb, Vivek Ajit Singh
core   +1 more source

Neuropeptide Y—Graphene Oxide Complexes Inhibit Amygdala NPY‐Receptor Expressing Glutamatergic Pathways and Selectively Remove Aversive Memory In Vivo

open access: yesAdvanced Science, EarlyView.
A graphene oxide nanocarrier presents neuropeptide Y specifically to NPY receptor‐expressing pathways in the amygdala, whose activation selectively suppresses aversive memory formation, without modulating anxiety responses. This circuit‐restricted drug release strategy may impact future design of neuropsychiatric therapies with limited off‐target ...
Elisa Pati   +10 more
wiley   +1 more source

Minimally Invasive Technique for PMMA Augmentation of Fenestrated Screws

open access: yesThe Scientific World Journal, 2015
Purpose. To describe the minimally invasive technique for cement augmentation of cannulated and fenestrated screws using an injection cannula as well as to report its safety and efficacy. Methods.
Jan-Helge Klingler   +7 more
doaj   +1 more source

Polydopamine Nanoparticle‐Mediated Precise Near‐Infrared Optical Stimulation for Cognitive Enhancement

open access: yesAdvanced Science, EarlyView.
Polydopamine nanoparticles enable a precise, non‐genetic, and transcranial neuromodulation strategy via near‐infrared photothermal stimulation. By activating TRPV1 channels, this approach specifically enhances hippocampal gamma oscillations, thereby rescuing spatial memory deficits in models of perioperative neurocognitive disorder.
Yan‐Bo Zhou   +10 more
wiley   +1 more source

Performance Estimation and Ex Vivo Validation of Untethered Magnetic Robots in Soft Tissue

open access: yesAdvanced Science, EarlyView.
This study presents an empirical model that quantitatively predicts the step‐out frequency of screw‐type untethered magnetic robots (UMRs) in soft viscoelastic environments, including ex vivo brain tissue. By integrating key parameters into a dimensionless framework, the model enables estimation of robot performance across a range of biological ...
Leendert‐Jan W. Ligtenberg   +19 more
wiley   +1 more source

Comparison of the Effect of Diameters and Numbers of Cannulated Screws and Headless Compression Screws on the Reduction Stability in Transverse Patellar Fractures: A Finite Element Model Study [PDF]

open access: yes, 2017
WOS: 000418448300002Background: Patella fractures constitute 1% of skeletal trauma. Transverse patella fractures are the most common types of patellar fractures.
Selami Karadeniz   +6 more
core   +1 more source

Home - About - Disclaimer - Privacy