Results 91 to 100 of about 25,080 (308)
Online sensor testing through superposition of encoded stimulus. [PDF]
Online monitoring remains an important requirement for a range of microsystems. The solution based on the injection of an actuating test stimulus into the bias structure of active devices holds great potential.
Bunyan, J. +9 more
core
A label free electrochemical nanobiosensor study [PDF]
Nano-porous silicon (PS) is an attractive material for incorporation into biosensors, because it has a large surface area combined with the ability to generate both optical and electrical signals. In this paper, we describe a label-free nanobiosensor for
Turner, Anthony P. F. +19 more
core +1 more source
A high‐capacity polyimide‐linked porous organic polymer (HAT‐PTO) incorporating numerous redox‐active centers is synthesized via a hydrothermal reaction, delivering a high theoretical capacity of 484 mAh g−1. In situ hybridization with carboxyl‐functionalized multiwalled carbon nanotubes enhances conductivity and stability, achieving 397 mAh g−1 at C ...
Arindam Mal +7 more
wiley +1 more source
Development of a Capacitive Pressure Sensor Based on Nanoporous Anodic Aluminium Oxide
Capacitive pressure sensors make pressure sensing technology more accessible to a wider range of applications and industries, including consumer electronics, automotive, healthcare etc.
Trishna Moni Das +3 more
doaj +1 more source
Analysis and Optimization of Noise Response for Low-Noise CMOS Image Sensors [PDF]
CMOS image sensors are nowadays widely used in imaging applications and particularly in low light flux applications. This is really possible thanks to a reduction of noise obtained, among others, by the use of pinned photodiode associated with a ...
Molina, Romain +7 more
core +1 more source
Electrically Readable Lateral Flow Assay Using Organic Transistors for Diagnostic Applications
Electrolyte‐gated organic field‐effect transistors (EGOFETs) are integrated with lateral flow (LF) paper fluidics to create a reusable, portable, and low‐cost point‐of‐care (PoC) diagnostic test. The devices are validated for Human Immunoglobulin G detection, achieving high sensitivity (0.1 fm), selectivity, and reproducibility with rapid results in 20–
María Jesús Ortiz‐Aguayo +4 more
wiley +1 more source
Ion‐Reconfigurable “N”‐Shaped Antiambipolar Behavior in Organic Electrochemical Transistors
A unique N‐shaped negative differential transconductance (NDT) characteristics is demonstrated in single‐polymer organic electrochemical transistors through a sequential doping–redox–doping process driven by iodide ions. This redox‐driven mechanism enables low‐voltage, ion‐controlled reconfigurability and tunable current modulation, allowing seamless ...
Debdatta Panigrahi +11 more
wiley +1 more source
A cost-effective capacitive sensor system, SEN0193, was ruggedised, calibrated, and evaluated in both laboratory and field settings to assess sensor-to-sensor variability resulting from sensor placement in the soil. Experimental data underwent regression
Amina Raheja +5 more
doaj +1 more source
Partial discharge on-line monitoring for HV cable systems using electro-optic modulators
A technique for the remote inspection and monitoring of partial discharge (PD) activity using an optical network is described. The network uses a LiNbO3 modulator to modulate the intensity of the transmitted laser light approximately proportional to the ...
Pommerenke, David +9 more
core +2 more sources
Energetic Offset in Organic Solar Cells‐ Importance, Confusion and Outlook
Energetic offsets in organic solar cells (OSCs) remain a subject of debate due to measurement‐ and lab‐dependent discrepancies. This Perspective clarifies the physical origins of these variations and identifies temperature‐dependent electro‐optical methods as a reliable approach to obtain consistent offset values.
Nakul Jain +5 more
wiley +1 more source

