Results 1 to 10 of about 856 (117)
During the switching on/off of shunt capacitor banks in substations, vacuum circuit breakers (VCBs) are required to switch off or to switch on the capacitive current.
Ming Yang, Wenxia Sima, Mi Zou
exaly +3 more sources
System-Based Testing of Protection for Center-Tapped Shunt Capacitor Banks
In power systems, capacitor banks play a significant role in improving voltage profiles, reducing losses, and adjusting power factors. Security measures must be implemented quickly and reliably to protect them from a wide range of threats.
Senthil Krishnamurthy
exaly +3 more sources
The problem regarding the optimal integration of efficient reactive power compensation in radial and meshed distribution networks using fixed-step capacitor banks and distribution static compensators (D-STATCOMs) is addressed in this research paper by ...
Oscar Danilo Montoya Giraldo +2 more
exaly +3 more sources
New solutions for controlled compensating devices [PDF]
The article presents material, which is based on the results of the analysis of literature sources on automatic devices for regulating reactive power in power supply systems. In addition, this article provides information regarding the operability of the
Karimov Raxmatillo Ch. +3 more
doaj +1 more source
On-Line Monitoring of Shunt Capacitor Bank Based on Relay Protection Device
In modern power systems, the installation of a shunt capacitor bank is one of the cheapest and most widely used methods for improving the voltage profile.
Yifeng Lin, Jingfu Gan, Zengping Wang
doaj +1 more source
On the functioning of capacitor banks in smart grids [PDF]
The amount of electronic equipment is increasing in created smart grids. This equipment introduces distortions into the electrical network, due to which the voltages at the network nodes, and hence the currents, become nonsinusoidal. The paper is devoted
Kovernikova Lidiia
doaj +1 more source
In order to solve the coordinated optimization problem of distributed generation (DG), on‐load tap changer (OLTC) and capacitor banks, a dynamic reactive power optimization (DRPO) method based on fuzzy time clustering is proposed.
Yuqi Ji +6 more
doaj +1 more source
THE METHODS OF REACTIVE POWER COMPENSATION IN THE 25 kV, 50 Hz CONTACT NETWORK [PDF]
The article analyses theoretical and practical solutions of reactive power compensation in the power grid of 25 kV, 50 Hz of the catenary. The article presents theoretical and practical studies (by providing circuits for connecting capacitor banks ...
Lionginas LIUDVINAVIČIUS
doaj +1 more source
The influence of capacitor banks on transformer load current [PDF]
This paper deals with the influence of capacitor banks used for reactive energy compensation on total load current of 10/0,4 kV/kV distribution transformers.
Jović Aleksandar S. +1 more
doaj +1 more source
Progammable Logic Controller (PLC) is a user friendly, microprocessor-based equipment that contains control functions of various types and levels of complexity.
Ferry Rahmat Astianta Bukit +2 more
doaj +1 more source