Results 141 to 150 of about 9,101,578 (286)

Magneto‐responsive fibers and fabrics for soft systems

open access: yesFlexMat, EarlyView.
Abstract The combination of functional materials in fiber form has led to a surge in the integration of functional fibers and fabrics into soft systems that span sensing, communication, and actuation domains. A key subset is magnetic fibers and fabrics.
Hanlin Zhu   +8 more
wiley   +1 more source

Illuminating point‐of‐care diagnostics with aggregation‐induced emission biosensors

open access: yesFlexMat, EarlyView.
This review highlights the application of aggregation‐induced emission luminogens (AIEgens) in point‐of‐care (POC) diagnostics for disease biomarker detection. It systematically examines a range of biosensing platforms, including lateral flow immunoassays, microfluidic chips, and electrochemiluminescence sensors, alongside their utility in detecting ...
Danni Hu   +3 more
wiley   +1 more source

Water‐driven dispersible fiber electrode arrays for position‐dependent intracardiac electrophysiological recording

open access: yesFlexMat, EarlyView.
Abstract Intracardiac electrophysiological recording plays an essential role in identifying abnormal cardiac electrical activity and guiding arrhythmia diagnosis and treatment planning. A key challenge for minimally invasive intracardiac electrodes is to combine reliable transvascular delivery with stable and compliant endocardial contact.
Jinyang Mao   +7 more
wiley   +1 more source

Safety of Implantable Cardiac Rhythm Management Devices. [PDF]

open access: yes
Life-saving treatments, such as pacemakers (PM), implantable cardiac defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices, are used for numerous cardiac conditions.
Gomeyi, Larin,
core  

Energy System for Wearables

open access: yesInterdisciplinary Materials, EarlyView.
This review systematically summarizes wearable energy systems, including energy demand, key technical challenges, multi‐channel energy harvesting, flexible energy storage and system integration. We discussed multi‐source hybrid energy harvesting and intelligent energy management in detail, emphasizing their roles in system performance and application ...
Yanjiao Teng   +9 more
wiley   +1 more source

Organic electrochemical transistors for neural recording and modulation: From mixed‐conduction physics to closed‐loop biointerfaces

open access: yesInfoMat, EarlyView.
OECT‐based neural interfaces integrate mixed ionic‐electronic transduction, soft biointegration, multimodal sensing, and closed‐loop modulation, enabling adaptive recording, neurochemical monitoring, and intelligent therapeutic strategies. Abstract Next‐generation neural interfaces increasingly aim to couple neural recording with local processing and ...
Chao Zhao   +10 more
wiley   +1 more source

Iron deficiency in heart failure: Epidemiology, diagnostic criteria and treatment modalities

open access: yes
ESC Heart Failure, Volume 12, Issue 2, Page 723-726, April 2025.
Stephan von Haehling
wiley   +1 more source

Accuracy of Large Language Model Chatbots in Retrieving MRI Safety Conditions for Medical Implants

open access: yesJournal of Magnetic Resonance Imaging, EarlyView.
ABSTRACT Background Retrieving MRI safety conditions for implanted devices is increasingly complex and time‐consuming. Purpose To evaluate the accuracy of internet‐enabled large language model (LLM) chatbots in retrieving implant‐specific MRI safety conditions, using manufacturer documentation as the reference standard.
Ariel Kerpel   +9 more
wiley   +1 more source

TricValve System Implantation in Patients With Cardiac Implantable Electronic Devices: A Multicentre Observational Study. [PDF]

open access: yesEur J Cardiothorac Surg
Osipenko K   +28 more
europepmc   +1 more source

Safety of bioelectrical impedance analysis in patients with cardiac implantable electronic devices: A systematic review

open access: yesJournal of Parenteral and Enteral Nutrition, EarlyView.
Abstract Background Bioelectrical impedance analysis is widely used in clinical settings to assess body composition, contributes to the management of various health conditions. However, for patients with cardiac implantable electronic devices, such as pacemakers and implantable cardioverter‐defibrillators, concerns about electromagnetic interference ...
H. Zweers   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy