Results 191 to 200 of about 14,363 (287)
Validation of a Curricular Map on Cardiac Implantable Electronic Devices (CIEDs) for Cardiac Anesthesia Trainees. [PDF]
F Zaky A +5 more
europepmc +1 more source
eOGO is an uncommon adverse event in patients on long‐term LVAD support. Thirty‐one eOGO patients were identified in a single‐centre HM3 implantation program. Twenty patients underwent percutaneous stenting. This treatment resulted in immediate LVAD flow improvement and yielded satisfactory quality‐of‐life results, with 62.5% patients assigned a fair ...
Anna Huang +14 more
wiley +1 more source
Surgical complications of cardiac implantable electronic devices: a systematic review and meta-analysis. [PDF]
Suárez-Paúl I +6 more
europepmc +1 more source
Toll‐like receptor 4 mediates lipopolysaccharide‐induced emesis
Background and Purpose Lipopolysaccharide (LPS) induces inflammation and sepsis through Toll‐like receptor 4 (TLR4) activation. Common laboratory animals do not exhibit emesis, but administration of LPS in piglets, cats, and dogs induces emesis via peripheral mechanisms.
Luping Liu +5 more
wiley +1 more source
Device-Removal, Reinfection, and Mortality After Staphylococcus aureus Bacteremia in Patients With Cardiac Implantable Electronic Devices. [PDF]
Bengtsen KH +16 more
europepmc +1 more source
ABSTRACT Background Cardiac amyloidosis is commonly associated with cardiac conduction disease. We sought to determine the prevalence of advanced conduction disease requiring a pacemaker in patients with known cardiac amyloidosis to evaluate current screening practices among patients receiving pacemakers.
Peishan Cai +4 more
wiley +1 more source
Evaluation of Wideband Pulse Sequences for Suppressing Image Artifacts in Children with Cardiac Implantable Electronic Devices. [PDF]
Aboyewa O +9 more
europepmc +1 more source
ABSTRACT Background and Aims Transvenous lead extraction (TLE) is increasingly performed for malfunction or infection of cardiac implantable electronic devices (CIED). Active mechanical rotational sheaths facilitate extraction and are available in short and long sizes, but it is unclear how many patients short active mechanical extraction sheaths ...
Caroline Wiederkehr +6 more
wiley +1 more source
Techniques for Transvenous Lead Extraction of Cardiac Implantable Electronic Devices: A Network Meta-Analysis. [PDF]
Santos CKM +3 more
europepmc +1 more source
ABSTRACT Introduction Mobile ambulatory cardiac telemetry (MCOT) use has increased over time; however, data on the prevalence and the impact of emergent arrhythmia notifications with MCOT remains unclear. We sought to determine the prevalence and clinical impact of emergent arrhythmia events in patients undergoing MCOT monitoring.
David Lin +11 more
wiley +1 more source

