Results 51 to 60 of about 8,820,967 (243)

Review of the European Society of Cardiology Guidelines for the management of infective endocarditis in patients with cardiac implantable electronic devices [PDF]

open access: yes, 2016
Review of the current guidelines for management of patients with infective endocarditis is provided in this article. The information about diagnosis, medical and surgical treatment of infective endocarditis in patients with cardiac implantable electronic
A.M. Shevelok   +7 more
core  

Impact of coronavirus disease (COVID-19) pandemic on physical activity of patients with cardiac implantable electronic devices-A remote monitoring study.

open access: yesPLoS ONE, 2022
ObjectivesThe study aims to investigate the impact of COVID-19 pandemic on physical activity and frequency of implantable cardioverter-defibrillator (ICD) therapies of patients with cardiac implantable electronic devices.Methods and resultsPhysical ...
Moritz T Huttelmaier   +6 more
doaj   +1 more source

Soft and Transient Bioelectronics Enabled by Polymer‐Free Ti3C2Tx MXene Hydrogels

open access: yesAdvanced Materials, EarlyView.
We present Ti3C2Tx MXene hydrogel (MXgel) bioelectronics, a soft, flexible, and fully transient platform for high‐fidelity neural recording and stimulation. MXgel bioelectronics exhibit exceptional electrical conductivities, low electrochemical impedances, and high charge injection capacities.
Raghav Garg   +15 more
wiley   +1 more source

Long-Term, Single-Centre Observation of Patients with Cardiac Implantable Electronic Devices

open access: yesMedicina, 2021
Background and Objectives: Electrotherapy is a valuable treatment method for patients with heart rhythm disturbances. There are very few observations of long-term patients treated with these techniques.
Roman Załuska   +4 more
doaj   +1 more source

A systematic review of ICD complications in randomised controlled trials versus registries: is our 'real-world' data an underestimation? [PDF]

open access: yes, 2015
Implantable cardioverter defibrillator (ICD) implantation carries a significant risk of complications, however published estimates appear inconsistent. We aimed to present a contemporary systematic review using meta-analysis methods of ICD complications ...
Ezzat, VA   +7 more
core  

Implantable devices: issues and challenges [PDF]

open access: yes, 2012
Ageing population and a multitude of neurological and cardiovascular illnesses that cannot be mitigated by medication alone have resulted in a significant growth in the number of patients that require implantable electronic devices.
Bazaka, Kateryna   +3 more
core   +1 more source

3D‐Printed Corneal Substitutes: Materials, Fabrication, and Preclinical Progress

open access: yesAdvanced Materials Technologies, EarlyView.
Successful clinical translation of 3D‐printed corneal substitutes relies on the interplay between the bioink properties, cellular component, and the fabrication process. These factors influence the critical properties of the construct, including optical transparency, mechanical stability, suture retention, that ultimately govern long‐term stromal ...
Shadi Moshayedi   +4 more
wiley   +1 more source

Remotely Monitored Cardiac Implantable Electronic Device Data Predict All‐Cause and Cardiovascular Unplanned Hospitalization

open access: yesJournal of the American Heart Association: Cardiovascular and Cerebrovascular Disease, 2022
Background Unplanned hospitalizations are common in patients with cardiovascular disease. The “Triage Heart Failure Risk Status” (Triage‐HFRS) algorithm in patients with cardiac implantable electronic devices uses data from up to 9 device‐derived ...
Camilla Sammut‐Powell   +5 more
doaj   +1 more source

Deep‐Tissue Light Generation via Whispering Gallery Mode Lasing From a Commercial Nylon Fiber for Biomedical Applications

open access: yesAdvanced Materials Technologies, EarlyView.
A dyed nylon fiber is implemented inside the scattering phantom and skin tissue. The deep‐tissue light generation via whispering gallery mode lasing is demonstrated, achieving a depth of >50 times transport mean free path in scattering phantom and 3 mm beneath skin.
Dongqin Ni   +4 more
wiley   +1 more source

Cardiac Implantable Electronic Device–Related Infection Due to Granulicatella adiacens [PDF]

open access: yes, 2019
Cardiac implantable electronic device-related infection is clinically challenging. Curative treatment commonly includes system removal. A case caused by occurred in a 32-year-old woman.
Schwerzmann, M.   +19 more
core   +2 more sources

Home - About - Disclaimer - Privacy