Results 101 to 110 of about 2,965,429 (175)

Electrogram Transition Patterns During Atrial Antitachycardia Pacing‐Mediated Termination

open access: yesJournal of Arrhythmia, Volume 42, Issue 5, October 2026.
Among 1,641 aATP‐terminated episodes in 38 patients, six electrogram transition patterns were identified. Irregular post‐aATP activity was the most common pattern preceding termination, regardless of pre‐aATP regularity (47% in regular and 63% in irregular pre‐aATP episodes). Episodes with irregular pre‐aATP activity took longer to terminate (median 13
Kosuke Nakasuka   +8 more
wiley   +1 more source

Cardiac Resynchronization as an Enabler of ARNI Efficacy: Insights From a Real‐World Cohort

open access: yesJournal of Arrhythmia, Volume 42, Issue 5, October 2026.
CRT provides the mechanical substrate that enables sacubitril/valsartan to maximize reverse remodeling. In this real‐world cohort, ARNI therapy was associated with greater improvement in left ventricular function and fewer clinically validated device‐detected HF events, particularly among CRT responders, supporting a synergistic interaction between ...
Amato Santoro   +10 more
wiley   +1 more source

5G Cloud‐Enabled Telemedicine for Remote Management of Heart Failure Patients With Implantable Cardioverter‐Defibrillators: A Multicenter Open‐Label Randomized Controlled Trial

open access: yesMedComm, Volume 7, Issue 10, October 2026.
Postoperative follow‐up for patients with implantable cardioverter‐defibrillators and cardiac resynchronization therapy defibrillators (ICD/CRT‐D) is often delayed in remote areas because of geographic barriers and limited healthcare resources, increasing the risk of adverse outcomes. The “Make Changes” study, was a prospective, multicenter, open‐label
Pan Li   +11 more
wiley   +1 more source

Long-term effects of cardiac resynchronisation therapy in patients with atrial fibrillation

open access: yes, 2008
To compare the effects of cardiac resynchronisation therapy (CRT) in patients with heart failure (HF) in either atrial fibrillation (AF) or sinus rhythm (SR)
Anthony, J   +10 more
core   +1 more source

Post‐Market Analysis of the Xenios Console With the Xlung Tubing Kit 230 for Extracorporeal Membrane Oxygenation After Cardiac Surgery

open access: yesArtificial Organs, Volume 50, Issue 10, Page 1464-1475, October 2026.
This study is a comprehensive post‐market analysis of the Xenios console and XLung kit 230 preconfigured ECMO tubing set in post‐cardiotomy applications. The performance of this device was evaluated and demonstrated in all key clinical areas, with an adequate safety profile.
Luca Conci   +9 more
wiley   +1 more source

Left Bundle Branch Block-associated Cardiomyopathy: A New Approach

open access: yesArrhythmia & Electrophysiology Review
Left bundle branch block (LBBB) is frequently associated with structural heart disease, and predicts higher rates of morbidity and mortality. In patients with cardiomyopathy (ejection fraction
Shunmuga Sundaram Ponnusamy   +2 more
doaj   +1 more source

Outcomes following cardiac resynchronisation therapy in older people. [PDF]

open access: yesAge Ageing, 2023
Safdar NZ   +11 more
europepmc   +1 more source

Association Between Sleep Quality and Oxidative Stress in Postoperative Cardiovascular Patients—A Pilot Study

open access: yesJournal of Sleep Research, Volume 35, Issue 5, October 2026.
In 15 postoperative cardiac surgery patients, venous reactive oxygen species (ROS) measured by electron spin resonance (ESR) over 48 h showed no consistent circadian pattern. Higher ROS was associated with lower subjective sleep efficiency and more nocturnal awakenings, but not with other sleep measures.
K. Krawczyk   +10 more
wiley   +1 more source

QT Interval Evaluation in Right Ventricular Pacing: Validation of a Novel Formula

open access: yesPacing and Clinical Electrophysiology, Volume 49, Issue 10, Page 1455-1463, October 2026.
ABSTRACT Background QT interval measurement in the presence of right ventricular pacing (RVP) represents a clinical challenge. We therefore aimed to derive and validate a formula for QT estimation during RVP in a large cohort of pacemaker patients. Methods and Results We prospectively enrolled 100 patients in a derivation cohort and 487 in a validation
Amr Abdin   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy