Results 61 to 70 of about 176,708 (300)
Nanotherapies for Atherosclerosis: Targeting, Catalysis, and Energy Transduction
Atherosclerosis management is hindered by poor drug targeting and plaque heterogeneity. Nanotechnology overcomes these barriers via three core strategies: (1) target‐engineered nanocarriers that achieve lesion‐specific precision via ligand modification, biomimetic camouflage, stimuli‐responsive release, and self‐propelling nanomotors; (2) catalytic ...
Yuqi Yang +4 more
wiley +1 more source
Carotid Web in Duplex Sonography: 4 Cases
Carotid web is a disease that is rarely found in patients with ischemic stroke, whereas it is more frequently observed in cryptogenic stroke patients. Fibromuscular dysplasia is known as the cause of carotid web, and it has been reported that carotid web
Minho Han, Kangsik Seo, Junghye Choi
doaj +1 more source
ObjectivesPrevious studies have confirmed the relations between inter-arm systolic blood pressure difference (IASBPD) and carotid artery plaque with the risk of cardiovascular diseases (CVD).
Cuijuan Yun +14 more
doaj +1 more source
The roles of endoglin gene in cerebrovascular diseases. [PDF]
Endoglin (ENG, also known as CD105) is a transforming growth factor β (TGFβ) associated receptor and is required for both vasculogenesis and angiogenesis.
Ma, Li, Su, Hua, Zhang, Rui, Zhu, Wan
core +2 more sources
A nano‐interception strategy disrupts pathogenic fibroblast–macrophage crosstalk in chronic heart failure. Scalable Prussian blue nanoparticles selectively sequester CCL2 via ultrahigh‐affinity binding, preventing CCR2+ macrophage recruitment and breaking a key fibro‐inflammatory circuit. This approach demonstrates robust efficacy in murine and porcine
Bo Chen +16 more
wiley +1 more source
Ultrasound imaging is vital for diagnosing carotid artery vascular lesions, highlighting the importance of accurately segmenting lumens in ultrasound images to prevent, diagnose and treat vascular diseases.
Yu Li +3 more
doaj +1 more source
Computational fluid dynamicaccuracy in mimicking changes in blood hemodynamics in patients with acute type IIIb aortic dissection treated with TEVAR [PDF]
Background: We aimed to verify the accuracy of the Computational Fluid Dynamics (CFD) algorithm for blood flow reconstruction for type IIIb aortic dissection (TBAD) before and after thoracic endovascular aortic repair (TEVAR).
Domenig, Christoph +5 more
core +1 more source
Micro‐ and nanorobots for targeted thrombolysis. This perspective elaborates on the clinical indication of blood clot disorders and current limitations for treatment. As a novel, alternative solution, micro‐ and nanorobots can be used to treat and break down thrombi.
Joshua M. Mesfin +3 more
wiley +1 more source
Optimization of Magnetic Milli‐Spinner for Robotic Endovascular Intervention
This work presents the design optimization of a multifunctional magnetic milli‐spinner for high‐speed propulsion and efficient clot debulking. The optimized design achieves an ultrafast swimming velocity of 55 cm/s (≈175 body lengths/s) in saline water, enabling stable upstream swimming against strong physiological flows and establishing magnetic milli‐
Lu Lu +3 more
wiley +1 more source
G3BP1 Succinylation at K413 is Critical for Cardiac Function by Modulating PI3K‐AKT‐mTOR Signal Axis
Schematic illustrating the impact of G3BP1 succinylation at K413 on cardiac function. In the healthy human heart, G3BP1 succinylation maintains homeostatic mTOR signaling. In patients with dilated cardiomyopathy (DCM) and heart failure (HF), G3BP1 de‐succinylation induces RagA expression and disrupts the binding of the TSC1/2 complex, leading to the ...
Yuan Zhang +9 more
wiley +1 more source

