ABSTRACT Purpose To develop and validate a practical, open‐source framework to overcome common issues in inline deployment of established offline MR reconstruction, including (1) scan disruption from lengthy reconstructions, (2) limited support for multi‐scan input reconstructions, (3) needs to adapt scripts for different raw‐data formats, and (4 ...
Zihan Ning +26 more
wiley +1 more source
Composite B-spline regularized delta functions for the immersed boundary method: Divergence-free interpolation and gradient-preserving force spreading. [PDF]
Gruninger C, Griffith BE.
europepmc +1 more source
Fat/Water Separation at 7 T Using a 3D Radial Sequence With Quasi‐Continuous Echo Times
ABSTRACT Purpose To achieve a reliable fat/water separation (FWS) at 7 T using a new 3D radial sequence and reconstruction workflow with quasi‐continuous TE sampling. Methods A 3D radial density‐adapted sequence with quasi‐continuous TE sampling was developed for a 7 T whole‐body MRI system.
Matthias Rohe +9 more
wiley +1 more source
Full Symmetry-Breaking of Electronic and Nuclear Dynamics for Low-Attosecond Resolution of Electronic Chirality. [PDF]
Xu T +7 more
europepmc +1 more source
ABSTRACT Purpose To develop a denoising technique for displacement encoding with stimulated echoes (DENSE) MRI that improves spatial resolution, efficiency, and accuracy, and enhances accessibility by implementing DENSE MRI at 0.55 T. Methods We developed a low‐rank denoising technique, which leverages multidimensional spiral cine DENSE MRI data for ...
Shu‐Fu Shih +9 more
wiley +1 more source
Motion-robust proton density fat fraction and T 2 ∗ mapping in supraclavicular adipose tissue using radial stack-of-stars imaging. [PDF]
Raspe J +5 more
europepmc +1 more source
Release and recapture of silica nanoparticles from an optical trap in weightlessness. [PDF]
Prakash G +3 more
europepmc +1 more source
Free‐Breathing Magnetization Transfer Imaging of the Lung at 0.55 T Using bSTAR
ABSTRACT Purpose To develop a clinically applicable method for magnetization transfer (MT) imaging of the lung at 0.55 T. Methods MT imaging of the chest was explored in healthy volunteers at 0.55 T using a self‐gated 3D half‐radial dual‐echo balanced steady‐state free precession sequence (bSTAR), a 2D multi‐slice gradient echo method (GRE) acquired in
Alexandra Braun +5 more
wiley +1 more source
SELFIE: Self‐Supervised Learning for Fast Dynamic Golden‐Angle Radial MRI
SELFIE enables reference‐free reconstruction for dynamic golden‐angle radial MRI. The self‐supervised training is enabled by leveraging the flexible temporal resolution of golden‐angle sampling to create self‐references and temporal sparsity. Evaluated on accelerated DCE‐MRI in patients with gynecological cancer and motion‐resolved free‐breathing ...
Melanie Schellenberg +7 more
wiley +1 more source
Reinforced molecular dynamics: Physics-infused generative machine learning model simulates protein motion. [PDF]
Kolossváry I.
europepmc +1 more source

