Results 161 to 170 of about 55,201 (283)

From Offline to Inline Without Pain: A Practical Framework for Translating Offline MR Reconstructions to Inline Deployment Using the Gadgetron Platform

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 1, Page 448-459, July 2026.
ABSTRACT Purpose To develop and validate a practical, open‐source framework to overcome common issues in inline deployment of established offline MR reconstruction, including (1) scan disruption from lengthy reconstructions, (2) limited support for multi‐scan input reconstructions, (3) needs to adapt scripts for different raw‐data formats, and (4 ...
Zihan Ning   +26 more
wiley   +1 more source

Fat/Water Separation at 7 T Using a 3D Radial Sequence With Quasi‐Continuous Echo Times

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 1, Page 96-108, July 2026.
ABSTRACT Purpose To achieve a reliable fat/water separation (FWS) at 7 T using a new 3D radial sequence and reconstruction workflow with quasi‐continuous TE sampling. Methods A 3D radial density‐adapted sequence with quasi‐continuous TE sampling was developed for a 7 T whole‐body MRI system.
Matthias Rohe   +9 more
wiley   +1 more source

Enhanced 2D Spiral Cine DENSE MRI Using Low‐Rank Denoising for Improved Apparent Signal‐to‐Noise Ratio, Spatial Resolution, Efficiency, Accuracy, and Accessibility

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 1, Page 403-419, July 2026.
ABSTRACT Purpose To develop a denoising technique for displacement encoding with stimulated echoes (DENSE) MRI that improves spatial resolution, efficiency, and accuracy, and enhances accessibility by implementing DENSE MRI at 0.55 T. Methods We developed a low‐rank denoising technique, which leverages multidimensional spiral cine DENSE MRI data for ...
Shu‐Fu Shih   +9 more
wiley   +1 more source

Phase‐Pole‐Free Images and Smooth Coil Sensitivity Maps by Regularized Nonlinear Inversion

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 1, Page 134-145, July 2026.
ABSTRACT Purpose Phase singularities are a common problem in image reconstruction with auto‐calibrated sensitivities due to an inherent ambiguity of the estimation problem. The purpose of this work is to develop a method for detecting and correcting phase poles in non‐linear inverse (NLINV) reconstruction of MR images and coil sensitivity maps ...
Moritz Blumenthal, Martin Uecker
wiley   +1 more source

Free‐Breathing Magnetization Transfer Imaging of the Lung at 0.55 T Using bSTAR

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 1, Page 203-213, July 2026.
ABSTRACT Purpose To develop a clinically applicable method for magnetization transfer (MT) imaging of the lung at 0.55 T. Methods MT imaging of the chest was explored in healthy volunteers at 0.55 T using a self‐gated 3D half‐radial dual‐echo balanced steady‐state free precession sequence (bSTAR), a 2D multi‐slice gradient echo method (GRE) acquired in
Alexandra Braun   +5 more
wiley   +1 more source

Accelerating MRI With Longitudinally‐Informed Latent Posterior Sampling

open access: yesMagnetic Resonance in Medicine, Volume 95, Issue 6, Page 3445-3461, June 2026.
ABSTRACT Purpose To accelerate MRI acquisition by incorporating the previous scans of a subject during reconstruction. Although longitudinal imaging constitutes much of clinical MRI, leveraging previous scans is challenging due to the complex relationship between scan sessions, potentially involving substantial anatomical or pathological changes, and ...
Yonatan Urman   +4 more
wiley   +1 more source