Results 1 to 10 of about 1,897 (158)

A Review of the Cascade Refrigeration System [PDF]

open access: yesEnergies, 2020
This paper provides a literature review of the cascade refrigeration system (CRS). It is an important system that can achieve an evaporating temperature as low as −170 °C and broadens the refrigeration temperature range of conventional systems.
Mingzhang Pan, Youcai Liang, Huan Zhao
exaly   +4 more sources

Thermodynamic Performance Analysis and Refrigerant Evaluation of Enhanced Cascade Vapor-Injection Refrigeration Systems [PDF]

open access: yesEntropy
To enhance the compression efficiency and refrigerant flow capacity for low-temperature refrigeration applications, the vapor-injection strategy is innovatively synthesized with two-stage cascade refrigeration systems.
Jidong Li   +3 more
doaj   +2 more sources

A Comprehensive Thermodynamic Assessment of Cascade Refrigeration System Utilizing Low GWP Hydrocarbon Refrigerants

open access: yesInternational Journal of Thermofluids, 2022
The thermodynamic performance of a two-stage vapor compression cascade refrigeration system using hydrocarbon refrigerants is studied extensively in this study.
Prof. Dr. Mohammad Monjurul Ehsan   +1 more
exaly   +3 more sources

A novel ultra-low temperature cascade refrigeration with dual auxiliary loop to enhance thermal performance [PDF]

open access: yesScientific Reports
A novel kind of cascade refrigeration cycle for ultra-low temperature applications has been proposed in the present work to enhance thermal performance with reduced carbon footprints more economically. The conventional cascade refrigeration system (CCRS)
Sachin Kumar   +3 more
doaj   +2 more sources

Cascaded superconducting junction refrigerators: Optimization and performance limits [PDF]

open access: yesApplied Physics Letters, 2021
We demonstrate highly transparent silicon–vanadium and silicon–aluminum tunnel junctions with relatively low sub-gap leakage current and discuss how a trade-off typically encountered between transparency and leakage affects their refrigeration performance.
Ronzani, Alberto   +6 more
openaire   +3 more sources

Energy and exergy analysis of a combined system cascade organic Rankine cycle and cascade refrigerat

open access: yesJournal of Thermal Engineering, 2021
In this paper, a new combined system is proposed for recovering thermal energy at medium temperature using a cascade organic Rankine cycle to feed a cascade refrigeration cycle.
Touaibi RABAH   +4 more
doaj   +1 more source

Performance comparison of the single-refrigerant cascade refrigerating system

open access: yesEnergy Reports, 2022
In the food refrigeration industry, the single-stage compression refrigerating system cannot meet the operating conditions of a high-pressure ratio when the evaporating temperature decreases. The cascade refrigerating system (CRS) is an alternative technical solution to solving the mentioned problem.
Zhili Sun   +11 more
openaire   +2 more sources

Thermodynamic evaluation of CO2 for ultra-low temperature refrigeration

open access: yesEnergy Conversion and Management: X, 2023
Carbon dioxide (CO2, R744) is the only refrigerant in the safest class by the ASHRAE 34 Standard in the group of natural refrigerants, with zero ozone depletion potential and a global warming potential of 1.
Cosmin-Mihai Udroiu   +4 more
doaj   +1 more source

Thermodynamic Analysis of an Innovative Cold Energy Storage System for Auto-Cascade Refrigeration Applications

open access: yesEnergies, 2023
The cooling capacity needed by ultra-low temperature apparatus cannot be reached economically with a single vapor compression refrigeration cycle due to the constraint of the high compressor pressure ratio.
Zhenzhen Liu   +3 more
doaj   +1 more source

The analysis of cascade refrigeration machine cycles efficiency using carbon dioxide [PDF]

open access: yesОмский научный вестник: Серия "Авиационно-ракетное и энергетическое машиностроение", 2021
The paper analyzes and proves the feasibility of improving the energy performance of low-temperature refrigeration machines operating on R744 using cascade design with R134a, R1234yf and R717 as refrigerants based on data the scientific study of two ...
A. S. Khrekin   +2 more
doaj   +1 more source