Results 141 to 150 of about 388 (185)
Some of the next articles are maybe not open access.

A controller for cascaded h-bridge multilevel inverter

2016 IEEE 7th Power India International Conference (PIICON), 2016
The multilevel inverter technology has gained a tremendous significance in the research area. This paper proposed a new controller for generating the switching sequence of power devices used in multilevel inverter to produce the desired output. An embedded code has been developed to control the switching states of different IGBT switches.
Ujjwal Kumar Kalla   +3 more
openaire   +1 more source

The Capacitor Voltage Balancing of Cascaded H-Bridge Multilevel Inverter

2019 IEEE International Conference on Mechatronics (ICM), 2019
The enhancing of the energy efficiency of the distribution AC systems under operating conditions within the framework of a FACTS (Flexible AC Transmission System). The concept is based on the using various types of power electronic controllers. In case of medium voltage applications most of the FACTS controllers are implemented on the multilevel ...
Oleg V. Nos   +4 more
openaire   +1 more source

Asymmetrical transistor-clamped H-bridge cascaded multilevel inverter

2012 IEEE Industry Applications Society Annual Meeting, 2012
This paper presents an asymmetrical cascaded multilevel inverter based on five-level transistor-clamped H-bridge power cell. Two-cell configuration with dc link voltage ratio of 4:1 is presented. The modulation method is based on the fundamental frequency switching. Analysis of the inverter output voltage and harmonics is presented.
Mohamad Fathi Mohamad Elias   +3 more
openaire   +1 more source

Management Algorithms for Cascaded H-Bridge Multilevel Inverters

2018 53rd International Universities Power Engineering Conference (UPEC), 2018
Multilevel inverters like the cascaded H-bridge topology provide multiple benefits compared to traditional B6-bridge inverters. Due to the modular structure of the inverter and the modulation techniques it is necessary to utilize management algorithms to achieve even energy distribution between all battery modules.
Markus Herzog   +3 more
openaire   +1 more source

SVPWM Control of Cascaded H-Bridge Multilevel Inverters

Applied Mechanics and Materials, 2012
To solve the problem of computational complexity in H bridge cascaded multilevel inverter (HBCMI) control, this paper proposes a simple space vector pulse width modulation control algorithm. Base on the topology configuration of HBCMI, the output voltage is deduced, which is the difference value between two-level inverter group output voltage formed by
Zheng Lu, Ju Xian Chen
openaire   +1 more source

Comparison of different topologies of cascaded H-Bridge multilevel inverter

2013 International Conference on Computer Communication and Informatics, 2013
This paper mainly deals with three different topologies of cascaded H-Bridge multilevel inverter. The Existing Topology is a general type of multilevel inverter and has two DC sources for each phase. In Proposed Topology-I the number of DC sources has been reduced to one for all the three phases and the usage of transformers comes into picture ...
K. N. V. Prasad   +3 more
openaire   +1 more source

Combined H-bridge cells cascaded transformers multilevel inverter

The 5th Annual International Power Electronics, Drive Systems and Technologies Conference (PEDSTC 2014), 2014
A single source less component structure of cascaded transformer H-bridge inverter is proposed in this paper. Depend on desired output voltage waveform; suggested topology consists of several basic cells. Each basic cell includes six unidirectional switches and two low frequency single phase insulated transformers.
Hossein Khoun jahan   +2 more
openaire   +1 more source

A modified cascaded H-bridge multilevel inverter for solar applications

2014 International Conference on Green Computing Communication and Electrical Engineering (ICGCCEE), 2014
In this paper, a modified cascaded H-bridge multilevel inverter (MLI) is proposed and designed for solar applications. Generally, as the level of conventional multilevel inverter increases, the required number of switches and size increases. The proposed topology is cascade of unit stages which involves 5 switches and two voltage source; moreover a ...
Mahajan Sagar Bhaskar Ranjana   +2 more
openaire   +1 more source

Load modeling and analysis of cascaded H-bridge multilevel inverter

2017 International Conference on Innovations in Electrical, Electronics, Instrumentation and Media Technology (ICEEIMT), 2017
Medium voltage multilevel inverters are used for high power applications. These will show a significant impact on the system dynamics because of their vast size and high power demand. Switching models for these multilevel inverters are already available through Mat lab/Simulink.
K. V. Ashok Kumar, R. Saravana Kumar
openaire   +1 more source

A fault detection method in cascaded H-bridge multilevel inverter

2016 IEEE International Conference on Power and Energy (PECon), 2016
This paper presents the switch-fault detection method in a cascaded H-bridge multilevel inverter (CHBMI). When the open-fault occurred on the H-bridge inverter switch of single-phase CHBMI, the body diode of fault switch can provide a freewheeling current path.
June-Hee Lee   +2 more
openaire   +1 more source