Results 1 to 10 of about 2,582 (177)
Experimental evaluation and accuracy analysis of inductive current transformers under realistic nonlinear and harmonic-rich load conditions [PDF]
This paper provides an experimental evaluation of two current transformers’ (CTs’) accuracy performance under linear and nonlinear load scenarios. Four performance indicators–measured RMS current, total harmonic distortion (THD), ratio error, and phase ...
Ben H. L. Daouli +4 more
doaj +2 more sources
In this research, modified PWM has been applied to the multilevel inverter (MLI) single-phase three-level diode clamp full bridge. Modified PWM is performed to produce minimum Total Harmonic Distortion (THD) the voltage because the quality of the good ...
Lucky Pradigta Setiya Raharja +3 more
doaj +2 more sources
Utilization of a New Meta Heuristic Algorithm to Minimize Total Harmonic Distortion (THD)
Recently applications of multilevel inverter become more convenient in power electronic. The Output closes to sinusoidal wave form, capability of creating high value of voltage or current, less blocking voltage on switches andâ¦, made multilevel ...
Hamed Hosseinnia, Daryoush Nazarpour
doaj +1 more source
Input Current THD Reduction via Virtual Resistant in EV Charger [PDF]
This paper investigates a fundamental issue in AC-DC rectifiers that are specifically used as charger for electric vehicle (EV), i.e. the total harmonic distortion (THD) of input current waveforms.
A. Mohammadi, M.A. Shamsi Nejad
doaj +1 more source
Analisa Pemasangan Filter Pasif Sebagai Peredam Harmonisa Akibat Beban Non Linier
Studi ini bertujuan menganalisa dampak pemasangan filter pasif pada beban listrik yaitu salah satu konsumen 3 phase PT. PLN. Variabel yang diamati adalah total harmonic distortion (THD) arus, THD tegangan, faktor daya dan putaran kwh meter elektromekanik.
Hari Prasetijo +3 more
doaj +1 more source
The increasing use of power electronics in various sectors leads to harmonic distortion in electric power systems, affecting power quality and equipment longevity.
Langlang Gumilar +4 more
doaj +1 more source
Harmonic distortion is one of the disturbances that most affects the quality of the electrical system. The widespread use of power electronic systems, especially power converters, has increased harmonic and interharmonic emission in a wide range of ...
Angel Arranz-Gimon +3 more
doaj +1 more source
To reduce total harmonic distortion (THD) and improve the power factor (PF) of a boost power factor correction (PFC) converter, here, the authors propose a non‐linear control algorithm that includes the feedforward correction (FC) algorithm in the ...
Hongda Song +7 more
doaj +1 more source
A Proposed Harmonic Monitoring System for Large Power Users Considering Harmonic Limits
Most power utilities within Southern Africa are faced with the challenges of harmonic distortion due to the high penetration of renewable energy sources (RES) and the use of electronic devices.
Rosalia Sinvula +2 more
doaj +1 more source
Feasibility Analysis for Power Transformer Expectancy and Loss of Life “A practical Case Study in Egyptian Electricity Transmission Company” [PDF]
Quality of power supply is now a major worldwide important issue making harmonic analysis an essential element in power system planning and design. Because of the power transformers are major components in power systems; this paper studies the impact of ...
Ibrahim Henidaq +3 more
doaj +1 more source