Results 231 to 240 of about 163,771 (279)
Some of the next articles are maybe not open access.
Cathodic Stripping Voltammetry of the Antibacterial Drug (Nitrofurantoin)
Analytical Letters, 1998Abstract Cathodic stripping voltammetry was used to determine the antibacterial drug Nitrofurantoin in phosphate buffer (pH 5.5). The adsorptive peak was observed at −0.173 V vs. Ag/AgCl. The peak response was characterized with respect to pH, preconcetration time, possible interferences, deposition potential, supporting electrolytes and other ...
Mahmoud Khodari +3 more
openaire +3 more sources
Voltammetry—Cathodic Stripping ☆
Cathodic stripping voltammetry (CSV) is an analytical technique used for the analysis of low levels of analytes (principally trace metals and sulfur containing organic compounds) in aqueous solutions, and is based on the measurement of a reductive ...
Eric P. Achterberg +2 more
core +4 more sources
VOLTAMMETRY | Cathodic Stripping
Cathodic stripping voltammetry (CSV) is an analytical technique used for the analysis of low levels of analytes (principally trace metals and sulfur containing organic compounds) in aqueous solutions, and is based on the measurement of a reductive ...
E.P. Achterberg +2 more
openaire +2 more sources
Determination of selenium in garlic by cathodic stripping voltammetry
Food Chemistry, 1999Abstract The selenium content in a garlic sample was determined on hanging mercury drop electrode (HMDE) using cathodic stripping voltammetry (CSV). In this method the dried garlic sample was digested in HNO3:HClO4 (1:1) by wet-digestion procedure. The CSV voltammogram in 0.1 M HCl solution showed a peak for Se at −0.56 V.
Somer, G, Inam, RECAİ
openaire +4 more sources
Manganese detection in marine sediments: anodic vs. cathodic stripping voltammetry
Three different electroanalytical techniques for the detection of manganese in marine sediments are evaluated. The anodic stripping voltammetry of manganese at an in situ bismuth-film-modified boron-doped diamond electrode and cathodic stripping ...
Richard Compton, Craig Banks
exaly +2 more sources
Cathodic stripping voltammetry of lead
Journal of Electroanalytical Chemistry, 1969Summary A method of lead analysis by the cathodic stripping voltammetry technique is suggested in the present study. The experimental conditions and the influence of these factors on the behaviour of lead and sensitivity of the analysis are discussed.
E. Hrabánková, J. Doležal, P. Beran
openaire +2 more sources
Cathodic stripping voltammetry of manganese
Journal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1969Summary A procedure is described for determining manganese in concentrations down to 10−9M using a cathodic stripping voltammetry technique. The conditions for the determination and the effect of the composition of the solution and of variations of the technique employed were studied.
E. Hrabánková, J. Doležal, V. Mašin
openaire +2 more sources
Cathodic stripping voltammetry of 5-fluorouracil
The Analyst, 1987An investigation has been carried out into the anodic differential-pulse polarographic and cathodic stripping voltammetric behaviour of the anticancer drug 5-fluorouracil at mercury indicator electrodes. The anodic peak, corresponding to the formation of a mercury salt, has been used for the determination of the drug in formulations with a relative ...
A J, Miranda Ordieres +4 more
openaire +2 more sources
Cathodic stripping voltammetry and adsorptive stripping voltammetry of selenium(IV)
Analytica Chimica Acta, 1988Abstract Cathodic stripping voltammetry of selenium(IV) in 0.1 M hydrochloric acid media yielded a nonlinear calibration graph for the concentration range 10−9−10−8 M. In this concentration range, adsorptive stripping voltammetry based on adsorption of the selenium/3,3′-diaminobenzidine complex on the surface of the hanging mercury drop electrode at ...
Věra Stará, Miloslav Kopanica
openaire +1 more source
Cathodic stripping voltammetry of HgSe
Journal of Electroanalytical Chemistry, 1994Abstract The problem with the presence of several cathodic stripping peaks for HgSe in acidic Se(IV) solutions has been addressed using linear sweep, cyclic, square-wave and differential pulse stripping voltammetry at a hanging-mercury-drop electrode (HMDE).
Gunnar Mattsson, Leif Nyholm, Åke Olin
openaire +1 more source

