Results 171 to 180 of about 655 (182)
Some of the next articles are maybe not open access.
Review of Palaeobotany and Palynology, 2012
Abstract This work presents palynological and palynofacies analyses from early Silurian Tanezzuft Formation shales recovered from core material of borehole CDEG-2a drilled in Dor el Gussa at the eastern margin of the Murzuq Basin, southern Libya. The material has yielded well-diversified palynomorph and chitinozoan assemblages and organic matter from
Paris, Florentin +8 more
openaire +2 more sources
Abstract This work presents palynological and palynofacies analyses from early Silurian Tanezzuft Formation shales recovered from core material of borehole CDEG-2a drilled in Dor el Gussa at the eastern margin of the Murzuq Basin, southern Libya. The material has yielded well-diversified palynomorph and chitinozoan assemblages and organic matter from
Paris, Florentin +8 more
openaire +2 more sources
Design and Research of UHVDC Earth Electrode Based on CDEGS Calculation
2023 8th Asia Conference on Power and Electrical Engineering (ACPEE), 2023Wenjie Ge +5 more
openaire +1 more source
Design and Analysis of Transformer Stations Grounding System Using CDEGS Software
2002In this paper the single phase to ground fault conditions in transformer station have been simulated in order to get spatial distribution of touch and step voltage on the ground surface. Spatial distribution is needed for checking and finding dangerous step and touch voltages. The field theory approach is used.
Nikolovski, Srete +2 more
openaire +1 more source
Analysis of grounding impedance spectrum based on CDEGS with different soil characteristics
2022 IEEE International Conference on High Voltage Engineering and Applications (ICHVE), 2022Qiheng Ma +5 more
openaire +1 more source
Computer Aided Design of Transformer Station Grouding System Using CDEGS Software
2002The fundamental concern of electrical power system is production, transmission and distribution of electric power to the end users – consumers in reliable and safe way with acceptable expense and sufficient voltage and frequency quality standard. The concept of reliable and safe electric power supply can quantitatively be valued by means of power ...
Nikolovski, Srete, Klaić, Zvonimir
openaire
Computer Aided Design of Transformer Station Grouding System Using CDEGS Software
2003In this paper a computer-aided design of transformer station grounding system is presented. The fault conditions in a transformer station can produce huge damages on transformer station equipment if the grounding system is not designed properly. A well designed grounding system is a very important part of the project for transformer station design as a
openaire
2009
This paper presents computations and measurements of the electric and magnetic fields produced by busbars, transformers and transmission line structures outside the transformer station in transmission power station TS 110/10(20) kV. The fundamental sources of low frequency electromagnetic fields in the transformer station are the primary elements of ...
Klaić, Zvonimir +2 more
openaire +1 more source
This paper presents computations and measurements of the electric and magnetic fields produced by busbars, transformers and transmission line structures outside the transformer station in transmission power station TS 110/10(20) kV. The fundamental sources of low frequency electromagnetic fields in the transformer station are the primary elements of ...
Klaić, Zvonimir +2 more
openaire +1 more source