Comparison of Platelet Counts by CellDyn Sapphire (Abbot Diagnostics), LH750 (Beckman Coulter), ReaPanThrombo Immunoplatelet Method (ReaMetrix), and the International Flow Reference Method, in Thrombocytopenic Blood Samples

open access: yesCytometry Part B - Clinical Cytometry, 2010
AbstractBackground:We compared the international flow reference method (IRM) platelet counts with those obtained from CellDyn Sapphire (impedance and optical counts), LH750 (impedance counts), and the flowcytometry based ReaPanThrombo Immunoplatelet method (ReaMetrix).
Papagudi G Subramanian   +2 more
exaly   +4 more sources

Neutrophil CD64 expression – comparison of two different flow cytometry protocols on EPICs MCL and the Leuko64™assay on a Celldyn Sapphire haematology analyser

open access: yesScandinavian Journal of Clinical and Laboratory Investigation, 2015
To evaluate the Trillium Diagnostics Leuko64(™) assay on Abbott Celldyn Sapphire haematology analyser compared to two flow cytometry protocols on Beckman Coulter EPICS MCL flow cytometer.CD64 expression on neutrophils was determined by two flow cytometry protocols and by a commercial assay on an automatic haematology analyser.
Oskar, Eriksson   +3 more
openaire   +3 more sources
Some of the next articles are maybe not open access.

Related searches:

Automated Counting of Cells in Cerebrospinal Fluid Using the CellDyn-4000 Haematology Analyser

Clinical Chemistry and Laboratory Medicine, 2002
Counting of cells in cerebrospinal fluid is currently performed manually. Because of the inherent analytical and economical disadvantages, we attempted to introduce a fully automated method. Therefore, we validated the Abbott CellDyn-4000 haematology analyser for counting cells in cerebrospinal fluid. The analyser was used in its standard configuration
Johannes J M L Hoffmann
exaly   +3 more sources

A Second-Generation Blood Substitute (Perfluorodichlorooctane Emulsion) Generates Spurious Elevations in Platelet Counts From Automated Hematology Analyzers

open access: yesAnesthesia and Analgesia, 2000
Perfluorocarbon emulsions (PFEs) appear as platelets in automated cell counters, which may affect samples from thrombocytopenic patients (less than 100,000/mu L). Therefore, we mixed clinically relevant concentrations of perfluorodichlorooctane (Oxyfluor(
Wayne L Chandler   +2 more
exaly   +2 more sources

Evaluation of the Sysmex XT-2000iV Hematology Instrument for Use With Feline Blood [PDF]

open access: yes, 2009
The objective of this study was to evaluate the Sysmex XT-2000iV with respect to its use with samples from the feline species. The Sysmex XT-2000iV is a flow cytometer that analyzes 31 hematological parameters and is based on the principles of multi ...
Weissenbacher, S
exaly   +3 more sources

Neutrophil CD64 Expression – Comparison of Two Different Flow Cytometry Protocols on EPICs MCL and the Leuko64™ Assay on a Celldyn Sapphire Haematology Analyser

Scandinavian Journal of Clinical and Laboratory Investigation, 2015
Malgorzata Karawajczyk   +1 more
exaly  