Results 71 to 80 of about 247,547 (353)
Micro‐ and nanorobots for targeted thrombolysis. This perspective elaborates on the clinical indication of blood clot disorders and current limitations for treatment. As a novel, alternative solution, micro‐ and nanorobots can be used to treat and break down thrombi.
Joshua M. Mesfin +3 more
wiley +1 more source
Access via the femoral vein [PDF]
Central venous access via the femoral vein (FV) is safe, relatively easy and very usual in infants and children undergoing cardiac surgery for congenital heart disease. It has a low insertion-related complication rate.
Kruessell, Markus +3 more
core
Bacteriophage K for reduction of Staphylococcus aureusbiofilm on central venous catheter material
The purpose of this project was to determine whether bacteriophage can reduce bacterial colonization and biofilm formation on central venous catheter material.
M. Lungren +5 more
semanticscholar +1 more source
Strategic Design of Soft Actuators in Translational Medical Robotics for Human‐Centered Healthcare
Soft robotics enables biocompatible, compliant medical devices, but clinical translation requires design‐driven engineering beyond materials. This perspective reviews implantable, surgical, and wearable systems by actuation mechanism, highlighting how optimized architectures and integration improve mechanical interfacing, adaptability, and durability ...
Ho Jun Jin +3 more
wiley +1 more source
Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. [PDF]
OBJECTIVE: Circulatory shock is a life-threatening syndrome resulting in multiorgan failure and a high mortality rate. The aim of this consensus is to provide support to the bedside clinician regarding the diagnosis, management and monitoring of shock.
A Babaev +157 more
core +5 more sources
Optimization of Magnetic Milli‐Spinner for Robotic Endovascular Intervention
This work presents the design optimization of a multifunctional magnetic milli‐spinner for high‐speed propulsion and efficient clot debulking. The optimized design achieves an ultrafast swimming velocity of 55 cm/s (≈175 body lengths/s) in saline water, enabling stable upstream swimming against strong physiological flows and establishing magnetic milli‐
Lu Lu +3 more
wiley +1 more source
Nitrosyl heme emerges as an extracellular nitrodilator that dilates arteries without crossing the cell membrane. Instead, heme‐NO mobilizes NO moieties from a preformed intracellular NO store within vascular smooth muscle, providing both functional and chemical evidence for the NANOS model, revealing a previously unrecognized mechanism of arterial ...
Taiming Liu +9 more
wiley +1 more source
Assessing the Burden of Unnecessary Central Venous Catheters in Patients on Medical-Surgical Floors [PDF]
Project goals: Our project goals are to: a) assess the burden of unnecessary PICCs and other non-tunneled central lines on med-surg units at TJUH and b) understand the underlying reasons behind the problem.
Blum, MD, Justine +6 more
core +1 more source
Estimated central blood volume in cirrhosis [PDF]
The estimated central blood volume (i.e., blood volume in the heart cavities, lungs and central arterial tree) was determined by multiplying cardiac output by circulatory mean transit time in 19 patients with cirrhosis and compared with sympathetic ...
Arendt +39 more
core +1 more source
BackgroundCentral venous catheter (CVC) and hemodialysis (HD) catheter usage are associated with complications that occur during catheter insertion, dwell period, and removal.
P. Napalkov +4 more
semanticscholar +1 more source

