Results 121 to 130 of about 26,146 (270)

Devices and methods of operation thereof for providing stable flow for centrifugal compressors [PDF]

open access: yes, 2008
Centrifugal compressor flow stabilizing devices and methods of operation thereof are disclosed that act upon the flow field discharging from the impeller of a centrifugal compressor and modify the flow field ahead of the diffuser vanes such that flow ...
Jett, Thomas A.   +2 more
core   +1 more source

Innovative development and structural behavior of hollow columns using inflatable molds

open access: yesStructural Concrete, EarlyView.
Abstract This study introduces a novel approach for constructing hollow columns using precast (PC) methods enhanced by inflatable air tubes as internal molds. The proposed method addresses practical challenges in conventional hollow column construction, such as limited constructability, high production cost, and interference between internal molds and ...
Soo Hyung Kim   +3 more
wiley   +1 more source

Full load testing in the platform module prior to tow-out: A case history of subsynchronous instability [PDF]

open access: yes
An electric motor driven centrifugal compressor to supply gas for further compression and reinjection on a petroleum production platform in the North Sea was examined.
Fulton, J. W.
core   +1 more source

Processing Stabilization of Polyolefin Recyclates Using Alditols in Combination With α‐Tocopherol: A Sustainable Alternative to Phosphites

open access: yesJournal of Vinyl and Additive Technology, EarlyView.
A novel bio‐based stabilizer system significantly improves the quality of polyolefin recyclates during multiple recycling cycles. ABSTRACT This study introduces a novel bio‐based stabilizer system for polyolefin recyclates that combines alditols with small amounts of α‐tocopherol as a sustainable alternative to conventional phosphite additives. The aim
Kim Hao Ng   +3 more
wiley   +1 more source

Percutaneous Intervention in External Outflow Graft Obstruction of Magnetically Levitated Left Ventricular Assist Device: Long‐Term Follow‐Up and Quality of Life

open access: yesArtificial Organs, EarlyView.
eOGO is an uncommon adverse event in patients on long‐term LVAD support. Thirty‐one eOGO patients were identified in a single‐centre HM3 implantation program. Twenty patients underwent percutaneous stenting. This treatment resulted in immediate LVAD flow improvement and yielded satisfactory quality‐of‐life results, with 62.5% patients assigned a fair ...
Anna Huang   +14 more
wiley   +1 more source

Field verification of lateral-torsional coupling effects on rotor instabilities in centrifugal compressors [PDF]

open access: yes
Lateral and torsional vibration data obtained on a centrifugal compressor train which had shaft instabilities and gear failures is examined. The field data verifies that the stability of centrifugal compressors can be adversely affected by coincidence of
Szenasi, F. R., Wachel, J. C.
core   +1 more source

Thirty Years of Autologous Platelet Concentrates: From Platelet‐Rich Plasma to Platelet‐Rich Fibrin

open access: yesJournal of Periodontal Research, EarlyView.
This review highlights the 30 years of evolution of APCs, with a focus on their clinical applications and recent technological advancements. ABSTRACT Nearly three decades have now passed since autologous platelet concentrates (APCs) were introduced into clinical practice.
Richard J. Miron   +7 more
wiley   +1 more source

Experimental performance of a 13.65-centimeter-tip-diameter tandem-bladed sweptback centrifugal compressor designed for a pressure ratio of 6 [PDF]

open access: yes
A 13.65 cm tip diameter backswept centrifugal impeller having a tandem inducer and a design mass flow rate of 0.907 kg/sec was experimentally investigated to establish stage and impeller characteristics.
Klassen, H. A.   +2 more
core   +1 more source

Program for calculating total-efficiency of specific-speed characteristics of centrifugal compressors [PDF]

open access: yes, 1973
Program uses one-dimensional mean streamline analysis conducted at fixed stagnation conditions. Seven specific losses are calculated for each set of compressors geometric variables and inlet velocity diagram characteristics studied.
Galvas, M. R.
core   +1 more source