Results 31 to 40 of about 225,550 (207)

A novel technique for ligation of the cephalic vein reduces hemorrhaging during a two-in-one insertion of dual cardiac device leads

open access: yesIndian Pacing and Electrophysiology Journal, 2018
The cutdown technique for the cephalic vein is a common access route for transvenous cardiac device leads (TVLs), and sometimes one cephalic vein can accomodate two TVLs.
Takatsugu Kajiyama   +6 more
doaj   +1 more source

A Rare Anatomical Variation of the Termination of Right and Left Cephalic Veins

open access: yesCase Reports in Vascular Medicine, 2018
Clinically, the cephalic vein is preferred for haemodialysis in patients with chronic renal failure (CRF), to remove waste products from blood. The cut-down of cephalic vein in the deltopectoral groove is preferred when superior vena caval infusion is ...
Raymond Saa-Eru Maalman   +3 more
doaj   +1 more source

Flowcytometric assessment of fetomaternal hemorrhage during external cephalic version at term [PDF]

open access: yes, 2008
External cephalic version (ECV) at term is a safe procedure and reduces the incidence of cesarean sections for breech presentation. One of the known complications, however, is an ECV-related disruption of the placental barrier and a subsequent ...
Toth, Bettina   +13 more
core   +2 more sources

A cephalic vein drained into one of the double axillary veins through the pectoralis major muscle [PDF]

open access: yes, 2016
Although the cephalic vein follows a fairly consistent course, numerous variants have been reported. We found a rare anatomical presentation of the cephalic vein in a 43-year-old Korean male cadaver.
Yoon, S. P.   +3 more
core   +1 more source

Two different variants of the jugulocephalic vein with supraclavicular course

open access: yesFolia Morphologica, 2020
The jugulocephalic anastomosis is a rare anatomical variant which normally undergoes atrophy during embryonic development. We found 2 cases of the jugulocephalic vein variant with supraclavicular course in Korean male cadavers.
W.-J. Lee   +4 more
doaj   +1 more source

Radio-cephalic fistula recovered with drainage to forearm basilic vein [PDF]

open access: yes, 2017
Dysfunction problems with vascular access are a concern to patients and dialysis units. The vascular surgeon should analyse such dysfunction and perform a careful assessment of the vascular network in order to find new fistula layouts.
Norton de Matos, António   +15 more
core   +1 more source

Supraclavicular course of the cephalic vein [PDF]

open access: yesInternational Journal of Case Reports and Images, 2014
Introduction: Vascular access for transvenous pacemaker and cardioverter defibrillator implants is frequently obtained by using the cephalic cutdown technique. Sometimes anatomical variations may limit insertion of one or several leads. We describe a case of a patient with an anomalous supraclavicular course of the left cephalic vein. Case Report: A 61-
Francisco Villegas   +4 more
openaire   +1 more source

A modified DRIL procedure by flow reversal of an aborted distal cephalic vein for critical hand ischaemia [PDF]

open access: yes, 2011
Treatment of dialysis access-related hand ischaemia with preservation of the access remains an issue. We report the case of a patient presenting critical hand ischaemia 2 years after proximalisation of a distal radio-cephalic fistula with preservation of
M. Czerny   +8 more
core   +1 more source

Morphology of Dorsal Venous Arch of Hand: A Cadaveric Study

open access: yesJournal of College of Medical Sciences-Nepal, 2019
Background: Venous network of hand is superficially placed and is easy to trace for clinical purposes. Ce-phalic vein on lateral aspect and basilic vein on medial aspect of the hand are clinically important for inva-sive and surgical procedures. Thus the
Nripendra Tiwari   +5 more
doaj   +1 more source

A rare anatomic variant of a single-conduit supraclavicular cephalic arch draining into the external jugular vein presenting with recurrent arteriovenous fistula stenosis in a hemodialysis patient

open access: yesJournal of Vascular Surgery Cases and Innovative Techniques, 2017
The cephalic arch is a common location of stenosis, especially in brachiocephalic fistulas. The cephalic arch has a number of anatomic variations. Cephalic arch stenoses are often resistant and have poor primary patency.
Eran Sim Wen Jun, MBBS   +2 more
doaj   +1 more source