Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer

Applied Radiation and Isotopes, 2015
The time constant of the output signal of the front-end readout circuit of a traditional gamma-ray spectrometer with a NaI(Tl)+PMT structure is affected by temperature, measurement environment and the signal transmission cable, so it is difficult to get a good resolution spectrum, especially at higher counting rates.
Guoqiang, Zeng   +5 more
openaire   +2 more sources

A Verilog-A model of a charge sensitive amplifier for a HV-CMOS pixel sensor

2016 13th International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design (SMACD), 2016
The use of hybrid pixel detectors in High Energy Physics (HEP) have allowed particle tracking reconstruction with an unprecedented precision. These detectors are expensive to assembly and the bump size limits the minimum pixel size. In order to overcome those limitations full monolithic pixels are being investigated.
Raimon Casanova, Sebastian Grinstein
openaire   +1 more source

A baseline restorer for charge-sensitive amplifiers in a 500-nm CMOS process

2018 IEEE 9th Latin American Symposium on Circuits & Systems (LASCAS), 2018
Charge-sensitive amplifiers (CSAs), widely used as front-ends in pulse processors for capacitive detectors, require a feedback network to set the operation point, deal with leakage currents and restore the baseline voltage upon the arrival of signals.
Angel Abusleme   +2 more
openaire   +1 more source

Fully Integrated Charge Sensitive Amplifier for Readout of Micromechanical Capacitive Sensors

2005 IEEE International Symposium on Circuits and Systems, 2005
This paper presents a charge sensitive amplifier (CSA) for readout of micromechanical capacitive sensors. The transfer function and noise performance together with noise optimisation are studied from a theoretical point of view. The feedback resistors of the CSA are implemented as long-channel MOS transistors to set the -3 dB corner frequency well ...
Mikko Saukoski   +3 more
openaire   +1 more source

Noise Analysis of Radiation Detector Charge Sensitive Amplifier Architectures [PDF]

open access: yes, 2008
In this work, a detailed comparison of four equivalent charge-sensitive, folded-cascode amplifiers in terms of noise performance is presented. A couple of complementary structures, one with a noise-optimised input nMOSFET and the other with a noise ...
T Noulis   +3 more
openaire   +2 more sources

Near-Quantum-Limited Operation of a Charge-Sensitive Electrical Amplifier

IEEE Transactions on Nanotechnology, 2010
Here, we report the operation of a superconducting single-electron transistor (S-SET) as a fast and nearly quantum-limited charge-sensitive amplifier. By operating the S-SET such that Cooper pair tunneling is resonant across both of its tunnel junctions, we are able to achieve an excellent charge sensitivity of δq = 1.6 × 10-6 e/√(Hz), while also ...
Alexander Rimberg   +4 more
openaire   +1 more source

A high resolution low cost charge sensitive amplifier

Nuclear Instruments and Methods, 1977
Abstract The development of a high resolution low cost charge sensitive amplifier was motivated by the installation of a liquid argon d E d x chamber in a high energy physics experiment (PLUTO experiment at DESY) for particle identification. The amplifiers were also used for the readout of a liquid argon shower counter. The properties of the
Brandt, S.   +4 more
openaire   +2 more sources

Performance Analysis of Charge Sensitive Amplifier

2024 International Conference on Integrated Circuits, Communication, and Computing Systems (ICIC3S)
Shipra Upadhyay   +5 more
openaire   +1 more source

CSAv3 -A Charge Sensitive Amplifier for Space Applications

2015
H S Cumming   +5 more
openaire   +1 more source

Charge-sensitive amplifier with non-critical components

Nuclear Instruments and Methods, 1966
openaire   +1 more source