Results 141 to 150 of about 128,978 (304)

Patient Dose Optimisation of Abdominopelvic Protocols During X‐Ray Imaging

open access: yesJournal of Medical Radiation Sciences, EarlyView.
This study evaluates organ doses in abdominopelvic radiography for both erect and supine positions, addressing dose optimisation concerns in Ghana. Using CalDose X and thermoluminescence dosimeters, organ doses and image quality were analysed, revealing significant dose reductions with optimised exposure parameters (70 kVp, 10 mAs, 110 cm FDD).
Emmanuel Ekem‐Ferguson   +3 more
wiley   +1 more source

Malpositioned Lines and Tubes on Chest Radiograph – A Concise Pictorial Review

open access: hybrid, 2020
Muthu Sakthivel   +3 more
openalex   +1 more source

The Importance of Patient Positioning in Radiography When Utilising Automatic Exposure Control

open access: yesJournal of Medical Radiation Sciences, EarlyView.
This study highlights the impact of inaccurate patient positioning on dose and image quality when utilising the automatic exposure control (AEC) for radiographic examinations. While the AEC serves to optimise radiation dose to patients, the results here demonstrate that poor positioning can lead to significant dose implications for patients.
Adam Steward   +3 more
wiley   +1 more source

Radiation Dose and Risk in the Radiological Investigation of Suspected Non‐Accidental Injury (NAI)

open access: yesJournal of Medical Radiation Sciences, EarlyView.
This study is a retrospective analysis of 362 skeletal surveys performed over a 5‐year period for children under 5 years of age for suspected non‐accidental injury. We present effective dose data and the associated risks of radiation exposure for initial and follow‐up examinations.
Tooba Zaidi, Rikki Nezich
wiley   +1 more source

Size‐specific dose estimates calculated using patient size measurements from scanned projection radiograph in high‐resolution chest computed tomography

open access: yesJournal of Medical Radiation Sciences, Volume 72, Issue 1, Page 85-92, March 2025.
This study established that patient's lateral width measurements made from scanned projection radiograph (SPR) is an overestimate compared to those measured from tomographic slices by about 10%. Size‐specific dose estimates (SSDE) calculated using lateral width measured from SPR correlates well with SSDE calculated using water equivalent diameter of ...
Ajit Brindhaban
wiley   +1 more source

Proposed Diagnostic Reference Levels for Frequently Performed Paediatric Radiographic Examinations

open access: yesJournal of Medical Radiation Sciences, EarlyView.
Paediatric diagnostic reference levels (DRLs) are weight‐stratified dose levels for typical medical imaging examinations for broadly defined types of equipment. The 75th percentiles of the FRLs across the nine X‐ray units from five centres in Australia were calculated as the proposed Local DRLs (LDRLs).
Edel Doyle   +4 more
wiley   +1 more source

Your C‐Arm May Be Dose Optimised but Is Your Surgical Procedure? The Evaluation and Dose Optimisation of Positioning Aids Used in Paediatric Image Guided Surgery

open access: yesJournal of Medical Radiation Sciences, EarlyView.
This study objectively evaluated the impact of positioning aids on radiation dose and image quality (IQ) in paediatric image guided surgery (IGS) and the potential for dose optimised imaging via the choice of positioning aid type selected for clinical use.
Dalia Dinham   +4 more
wiley   +1 more source