Results 161 to 170 of about 17,265,580 (249)

APOBEC3 activity and DNA polymerase‐ε deficiency are associated with distinct IDH1 R132 hotspot mutations

open access: yesMolecular Oncology, EarlyView.
Isocitrate dehydrogenase 1 (IDH1) mutations are highly recurrent in multiple human cancer types, including cholangiocarcinoma and glioma. IDH1 R132C is the most common IDH1 mutation in cholangiocarcinoma and likely arises from APOBEC3A‐ or APOBEC3B‐mediated deamination.
Kelly E. Butler   +3 more
wiley   +1 more source

Bridging the gap: a genetically validated avian chorioallantoic membrane platform for investigation of spontaneous circulating tumor cells

open access: yesMolecular Oncology, EarlyView.
We established the avian chorioallantoic membrane (CAM) assay as a scalable in vivo model for studying circulating tumor cells (CTCs). Human gastrointestinal tumors spontaneously released genetically validated CTCs that were detected across multiple platforms, demonstrating that the CAM model provides an accessible tool for investigating early cancer ...
Dennis Roth   +17 more
wiley   +1 more source

SPHINX31 acts as a SRPK1 inhibitor targeting the ATR/DNA‐PKcs/CHK1 replicative checkpoint to inhibit cell growth in non‐small cell lung cancer

open access: yesMolecular Oncology, EarlyView.
The kinase SRPK1 directly interacts with the protein TOPBP1 and regulates the pre‐mRNA splicing of WIZ thereby contributing to the activation of the ATR/CHK1 replicative checkpoint in response to replicative stress. This allows cancer cells' genomic stability and survival.
Amani Shreim   +17 more
wiley   +1 more source

Polarization‐resolved femtosecond Vis/IR spectroscopy tailored for resolving weak signals in biological samples using minimal sample volume

open access: yesFEBS Open Bio, EarlyView.
Unique biological samples, such as site‐specific mutant proteins, are available only in limited quantities. Here, we present a polarization‐resolved transient infrared spectroscopy setup with referencing to improve signal‐to‐noise tailored towards tracing small signals. We provide an overview of characterizing the excitation conditions for polarization‐
Clark Zahn, Karsten Heyne
wiley   +1 more source

A light‐triggered Time‐Resolved X‐ray Solution Scattering (TR‐XSS) workflow with application to protein conformational dynamics

open access: yesFEBS Open Bio, EarlyView.
Time‐resolved X‐ray solution scattering captures how proteins change shape in real time under near‐native conditions. This article presents a practical workflow for light‐triggered TR‐XSS experiments, from data collection to structural refinement. Using a calcium‐transporting membrane protein as an example, the approach can be broadly applied to study ...
Fatemeh Sabzian‐Molaei   +3 more
wiley   +1 more source

Single‐molecule DNA flow‐stretch assays for high‐throughput DNA–protein interaction studies

open access: yesFEBS Open Bio, EarlyView.
We describe an optimised single‐molecule DNA flow‐stretch assay that visualises DNA–protein interactions in real time. Linear DNA fragments are tethered to a surface and stretched by buffer flow for fluorescence imaging. Using λ and φX174 DNA, this protocol enhances reproducibility and accessibility, providing a versatile approach for studying diverse ...
Ayush Kumar Ganguli   +8 more
wiley   +1 more source

Analysing the significance of small conformational changes and low occupancy states in serial crystallographic data

open access: yesFEBS Open Bio, EarlyView.
This protocol paper outlines methods to establish the success of a time‐resolved serial crystallographic experiment, by means of statistical analysis of timepoint data in reciprocal space and models in real space. We show how to amplify the signal from excited states to visualise structural changes in successful experiments.
Jake Hill   +4 more
wiley   +1 more source

Optimizing photoactivation of PA‐mCherry for optical pooled CRISPR screens

open access: yesFEBS Open Bio, EarlyView.
Photoactivatable PA‐mCherry finds widespread use to optically tag individual cells. However, confocal 405 nm UV laser‐scanning (normal scan) is much less efficient than widefield UV illumination, limiting the use of PA‐mCherry on confocal instruments. We remedy this limitation by reporting that rapid and repeated confocal scanning with a low‐intensity,
Sravasti Mukherjee   +3 more
wiley   +1 more source

A Comparative Study on Visual Choice Reaction Time for Different Colors in Females

open access: yesNeurology Research International, 2014
Grrishma Balakrishnan   +5 more
doaj   +1 more source

Refinement of amino‐acid conformation vs. difference density maps in time‐resolved serial femtosecond crystallography data analysis

open access: yesFEBS Open Bio, EarlyView.
The dFoCC pipeline starts with observed DED and resting‐state coordinates, which are then used to generate a library of triggered states. Correlation analysis of the calculated DED features of each candidate vs observed DED permits quantitative evaluation of candidate structural quality.
Meng Iao Fong   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy