Results 41 to 50 of about 1,664 (293)

Fully Integrated Biopotential Acquisition Analog Front-End IC

open access: yesSensors, 2015
A biopotential acquisition analog front-end (AFE) integrated circuit (IC) is presented. The biopotential AFE includes a capacitively coupled chopper instrumentation amplifier (CCIA) to achieve low input referred noise (IRN) and to block unwanted DC ...
Haryong Song   +3 more
doaj   +1 more source

Multi-Channel Neural Recording Implants: A Review

open access: yesSensors, 2020
The recently growing progress in neuroscience research and relevant achievements, as well as advancements in the fabrication process, have increased the demand for neural interfacing systems. Brain−machine interfaces (BMIs) have been revealed to be
Fereidoon Hashemi Noshahr   +2 more
doaj   +1 more source

A 55 V, Six-Channel Chopper and Auto-Zeroing Amplifier with 6.2 nV/Hz Noise and −128 dB Total Harmonic Distortion

open access: yesEng
In this paper, a high-voltage chopper and ping-pong auto-zeroing operational amplifier was designed for industrial and automotive applications. Based on chopper stabilization, the proposed circuit introduces a novel chopper switch control signal that ...
Guolong Li   +5 more
doaj   +1 more source

Influence of Test Temperature and Test Frequency on Fatigue Life of Aluminum Alloy EN AW‐2618A

open access: yesAdvanced Engineering Materials, EarlyView.
The influence of test temperature and test frequency on the fatigue life of EN AW‐2618A is investigated. High‐cycle fatigue tests are performed at different test temperatures and frequencies on the 1000 h/230°C overaged state. Both test parameters reduce fatigue life due to time‐dependent damage mechanisms.
Ying Han   +5 more
wiley   +1 more source

Consideration of Bandwidth of Amplifier Block in Chopper Stabilization Amplifier [PDF]

open access: yes, 2016
This thesis presents a consideration of bandwidth of amplifier block in chopper stabilization amplifier. In the theory of the amplifier using chopper stabilization technique, Fourier series expansion often is used.
タンノ, コウイチ   +18 more
core  

A CMOS low-noise instrumentation amplifier using chopper modulation [PDF]

open access: yes, 2005
This paper describes a low-power, low-noise chopper stabilized CMOS instrumentation amplifier for biomedical applications. Low thermal noise is achieved by employing MOSTs biased in the weak/moderate inversion region, whereas chopper stabilization is ...
Bruun, Erik, Nielsen, Jannik Hammel
core   +1 more source

Polymer Interface Enables Reversible Quasi‐Solid Sulfur Conversion in Sodium‐Sulfur Batteries

open access: yesAdvanced Functional Materials, EarlyView.
The polymer interface enables a stable quasi‐solid sulfur conversion pathway in room‐temperature Na─S batteries. The coating regulates Na+ transport, stabilizes the cathode–electrolyte interphase, and accommodates mechanical stress, suppressing electrolyte decomposition and sulfur migration, thereby improving reaction uniformity, reducing polarization,
Reza Andaveh   +12 more
wiley   +1 more source

Bandgap‐Engineered AlGaAs/GaAs Heterostructures for Wavelength‐Selective Dual‐Polarity Photoelectrochemistry

open access: yesAdvanced Functional Materials, EarlyView.
Bandgap‐engineered AlGaAs/GaAs heterostructures exhibit wavelength‐selective dual‐polarity photoelectrochemistry, switching from photocathodic to photoanodic response depending on excitation wavelength. The polarity transition is governed by band‐selective absorption, built‐in electric‐field‐driven carrier transport, and interfacial charge‐transfer ...
Yukai Mao   +9 more
wiley   +1 more source

All‐Solution‐Processed HgTe Quantum Dot Photodetectors for Extended Short‐Wavelength Infrared Range Enhanced by Plasmonic ITO Nanocrystals

open access: yesAdvanced Functional Materials, EarlyView.
All‐solution‐processed, low‐cost extended short‐wavelength infrared photodetectors are realized by coupling colloidal HgTe quantum dots to plasmonic In2O3:Sn,F nanocrystals. Localized surface plasmon resonances boost and spectrally tailor light absorption between 1500 and 3000 nm, enabling responsivities above 40 A W−1.
Kseniia A. Sergeeva   +9 more
wiley   +1 more source

Infusible Extracellular Matrix Biomaterial Enhances Cell‐Specific Pro‐Repair Responses Following Acute Myocardial Infarction

open access: yesAdvanced Healthcare Materials, EarlyView.
We measure the cell‐specific responses of administering infusible ECM (iECM) in acute myocardial infarction (MI) across multiple timepoints. Using single‐nucleus RNA sequencing and spatial transcriptomics, we measure macrophage activation, fibroblast remodeling, increased vascular development, lymphangiogenesis, cardioprotection, and neurogenesis ...
Joshua M. Mesfin   +18 more
wiley   +1 more source

Home - About - Disclaimer - Privacy