Results 71 to 80 of about 182,048 (302)
Graphene nanoplatelet (0.1 wt.%) reinforcement significantly enhances the performance of β Ti‐28Nb‐35.4Zr alloy. Grain refinement, reduced water contact angle, and improved surface characteristics promote osteoblast adhesion and complete surface coverage after 7 days.
Khurram Munir +5 more
wiley +1 more source
Chronic total occlusion (CTO) angioplasty is one of the most challenging procedures remaining for the interventional operator. Recanalizing CTOs can improve exercise capacity, symptoms, left ventricular function and possibly reduce mortality.
James W. Tam +2 more
doaj +1 more source
The newer chronic total occlusion–specific intravascular ultrasound AnteOwl WR-based 3-dimensional wiring technique using the tip detection method allowed us easily to succeed in treating chronic total occlusion lesions that were previously ...
Satoshi Suzuki, MD +9 more
doaj +1 more source
Assembly of Cell‐Seeded 3D Printed Hydrogel Modules with Perfusable Channel Networks
Macroscale assembly was utilized to prepare perfusable tissue constructs from individually 3D printed hydrogel modules with embedded branched channel networks and port arrays for cell seeding. Novel multi‐material bioreactors were fabricated to facilitate the gluing of individual modules and the perfusion culture of assembled modular constructs seeded ...
Zachary J. Geffert +10 more
wiley +1 more source
Objectives: This study sought to examine the pre-interventional parameters for procedural success of CTO angioplasty and to assess improvement of Left ventricular ejection fraction after successful angioplasty of CTO. Background: Chronic total occlusions
Ahmed Magdy +3 more
doaj +1 more source
Radiation‐induced hypothyroidism follows head and neck radiotherapy due to oxidative stress and inflammation. Electrospun polycaprolactone scaffolds containing adenosine have potential to modulate thyroid repair. Scaffolds enhance thyrocyte proliferation, antioxidant enzymes glutathione peroxidase and catalase, reduce senescence and apoptosis markers ...
Maria Heim +5 more
wiley +1 more source
Effect of external PEEP in patients under controlled mechanical ventilation with an auto-PEEP of 5 cmH2O or higher. [PDF]
In some patients with auto-positive end-expiratory pressure (auto-PEEP), application of PEEP lower than auto-PEEP maintains a constant total PEEP, therefore reducing the inspiratory threshold load without detrimental cardiovascular or respiratory effects.
Amodeo, Guido +16 more
core +1 more source
We measure the cell‐specific responses of administering infusible ECM (iECM) in acute myocardial infarction (MI) across multiple timepoints. Using single‐nucleus RNA sequencing and spatial transcriptomics, we measure macrophage activation, fibroblast remodeling, increased vascular development, lymphangiogenesis, cardioprotection, and neurogenesis ...
Joshua M. Mesfin +18 more
wiley +1 more source
A 49-year-old man with CTEPH (pre-procedural mean pulmonary artery pressure: 36 mmHg) underwent balloon pulmonary angioplasty. Chronic total occlusion of the left inferior pulmonary artery trunk was observed.
Masashi Tamura +6 more
doaj +1 more source
Regulation of gap junction function; the role of nitric oxide. [PDF]
Myocardial ischemia resulting from sudden occlusion of a coronary artery is one of the major causes in the appearance of severe, often life-threatening ventricular arrhythmias.
Gönczi, Márton +3 more
core +2 more sources

