Results 91 to 100 of about 15,984 (208)
ABSTRACT Purpose To evaluate a third‐order motion‐compensated spin echo (M3‐MCSE) sequence at multiple cardiac phases on a clinical 3 T MRI scanner with ultra‐high performance (UHP) gradients (200 mT/m), compared with stimulated echo acquisition mode (STEAM) and second‐order MCSE (M2‐MCSE) for cardiac diffusion tensor imaging (cDTI).
Ke Wen +8 more
wiley +1 more source
5D Flow MRI Reveals Respiration‐Driven Changes in Blood Flow Energetics in Congenital Heart Disease
ABSTRACT Purpose Hemodynamic monitoring is essential for patients with right‐sided congenital heart disease (CHD). Respiration may have an increased impact on pulmonary flow in these patients that cannot be assessed by standard tools including 4D flow MRI. This study uses 5D flow MRI to assess respiratory‐cycle variations in flow energetics in patients
Thara Nallamothu +7 more
wiley +1 more source
ABSTRACT Purpose To deconvolve cardiac phase and hemodynamic effects in hyperpolarized (HP) [1‐13C]pyruvate and to develop a cardiac phase‐adjustable reconstruction framework. Methods Cardiac phase drift during dynamic acquisition of HP 13C MRS and its effect on dynamic signal fidelity were simulated using a digital cardiac phantom. A hemodynamic model
Sung‐Han Lin +5 more
wiley +1 more source
Minimally Invasive Porcine Model for Chronic Thromboembolic Pulmonary Hypertension
ABSTRACT To elucidate the complex pathophysiology of chronic thromboembolic pulmonary hypertension (CTEPH), a disease associated with bilateral fibrotic obstructions of the pulmonary arteries (PA) and microvascular changes, research relies on animal models, which often depend on invasive techniques, including open surgery.
Bianca Battilana +5 more
wiley +1 more source
ABSTRACT Background Poor cardiac MR image quality can prompt repeat examinations and hinder clinical decision‐making. Purpose To evaluate whether pre‐imaging clinical information, extracted using a large language model (LLM), is independently associated with cardiac MR image quality. Study Type Retrospective.
Hong Yu +6 more
wiley +1 more source
: Background: Manual clinical tests for shoulder instability rely heavily on subjective assessments of humeral head translation, making objective quantification challenging.
Kazuhisa Matsui, PT, PhD, MSc +3 more
doaj +1 more source
Gabor Primitives for Accelerated Cardiac Cine MRI Reconstruction
Accelerated cardiac cine MRI requires reconstructing spatiotemporal images from highly undersampled k-space data. Implicit neural representations (INRs) enable scan-specific reconstruction without large training datasets, but encode content implicitly in network weights without physically interpretable parameters.
Wenqi Huang 0003 +8 more
openaire +2 more sources
ABSTRACT Background Ebstein's anomaly (EA) is a congenital heart disorder involving tricuspid valve dysplasia and right heart abnormalities resulting in severe tricuspid regurgitation (TR). Multiple techniques assess regurgitation severity, but their correlation with EA severity markers remains unclear. Purpose To compare MRI techniques for quantifying
Eric Buffle +8 more
wiley +1 more source
ABSTRACT Background The demand for cardiac MRI is increasing with the growing burden of cardiovascular disease. However, conventional protocols require sequential acquisitions for multi‐breath‐hold 2D cine and 3D MR angiography (MRA), which is time‐consuming.
Ruixin Chen +7 more
wiley +1 more source
Deep‐Learning‐Based Image Reconstruction to Improve End‐Diastolic and Systolic Cardiac T1 Mapping
ABSTRACT Purpose To develop an image reconstruction method that enables increased spatial resolution cardiac T1 mapping in both the end‐diastolic and systolic phase, that shows high T1 agreement with the clinical standard. The resolution gain is achieved by increasing the acceleration rate of MOLLI single‐shot images to R = 4, while maintaining a ...
Daniel Amsel +10 more
wiley +1 more source

