Results 21 to 30 of about 9,614 (304)
The energetics of gas flow and contact erosion during short circuit arcing [PDF]
The processes governing the movement of short circuit arcs in circuit breakers are complex and variable and the detailed understanding of these processes is incomplete.
Weaver, P.M. +2 more
core +1 more source
Fault diagnosis of circuit breaker based on improved dynamic time warping algorithm
In order to accurately diagnose the fault of circuit breaker according to its condition monitoring data, a fault diagnosis method of circuit breaker based on improved dynamic time warping algorithm was proposed.
JIANG Zhihao, YU Qun, DONG Li
doaj +1 more source
In this paper, a new design is provided so that the Z-source circuit breaker with a mechanical switch operates quickly at a low-impedance fault. When the fault occurs, the Z-source circuit breaker uses an impedance network to generate forced current zero
Hyeon-Seung Lee +3 more
doaj +1 more source
We proposed a superconducting DC circuit breaker that can reliably cut off the fault currents in preparation for the DC system. It consists of a superconducting element and a mechanical DC circuit breaker.
Sang-Yong Park +3 more
doaj +1 more source
Key stress extraction and equivalent test method for hybrid DC circuit breaker
Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological ...
Chong Gao +4 more
doaj +1 more source
HVDC Circuit Breakers–A Review [PDF]
HVDC circuit breakers are of increasing importance, as multi-terminal high voltage DC (HVDC) transmission becomes a commercial reality. Multiple HVDC breaker technologies have been developed, and are starting to appear as proof-of-concept installations on real networks. Information about them is however distributed widely in the literature.
Mike Barnes +5 more
openaire +1 more source
The low-voltage circuit breakers are widely used to protect loads in the distribution system. Interruption reliability of circuit breakers is important because they are a protective device close to the customer.
Kun-A Lee, Young-Maan Cho
core +1 more source
A short circuit current evaluation method based on the branch fault current of the circuit breaker
With the rapid load growth and the increasing density of power grids, the overrun short-circuit current becomes increasingly aggravated. To accurately assess the short-circuit current level of the system is crucial to ensure the safe and stable operation
DONG Wei +5 more
doaj +1 more source
Arc motion and gas flow in current limiting circuit breakers operating with a low contact switching velocity [PDF]
Arc motion in low voltage (240 VAC) high current (10/sup 3/-10/sup 4/A.) current limiting-circuit breakers is dominated by arc root mobility. The mobility is influenced by the gas flow and gas composition in the contact region, but there is little ...
Weaver, P.M. +2 more
core +1 more source
Placement optimization of Multi-Type fault current limiters based on genetic algorithm
The fault current limiter (FCL) is an effective measure for improving system stability and suppressing short-circuit fault current. Because of space and economic costs, the optimum placement of FCLs is vital in industrial applications. In this study, two
Guofeng Jin +4 more
doaj +1 more source