Results 21 to 30 of about 39,622 (243)

Innovative X-ray control technology of high-voltage circuit breaker technical condition [PDF]

open access: yesE3S Web of Conferences, 2020
The paper presents the results of practical application of an instrumentation and analytical system (IAS) for X-ray control of minimum oil and SF6 circuit breakers. The capabilities of IAS are described and the technology for its implementation is given.
Darian Leonid   +2 more
doaj   +1 more source

Transient Characteristics Analysis of 500kV Parallel Circuit Breaker Based on Highly Coupled Split Reactor [PDF]

open access: yesE3S Web of Conferences, 2019
With the continuous expansion of power system capacity, parallel high-voltage circuit breakers with a Highly Coupled Split Reactor (HCSR) have a potential application for limitation of high short-circuit current. However, as the parallel circuit breakers
Xiang Changyuan   +3 more
doaj   +1 more source

Calculation of Last Current Loop Parameters and TRV Parameters in T100a Breaking Test of High Voltage Circuit-breakers

open access: yesJournal of Harbin University of Science and Technology, 2023
Asymmetric short-circuit fault breaking test T100a is an important test item of High-voltage AC Circuit-breakers. In non-effectively earthed neutral system the first pole to clear factor is 1.5 and the transient recovery voltage (TRV) has two or four ...
HE Ninghui   +5 more
doaj   +1 more source

Hybrid Z-Source Circuit Breaker with Thomson Coil for MVDC

open access: yesEnergies, 2023
Hybrid circuit breakers are the most promising circuit breakers among DC circuit breakers. Conventional hybrid circuit breakers complete fault current isolation by converting current to IGBT when fault current occurs.
Hyun-Seung Lee   +3 more
doaj   +1 more source

Providing decision support for the condition-based maintenance of circuit breakers through data mining of trip coil current signatures [PDF]

open access: yes, 2007
The focus of this paper centers on the condition assessment of 11kV-33kV distribution circuit breakers from the analysis of their trip coil current signatures captured using an innovative condition monitoring technology developed by others.
Campbell, A.   +4 more
core   +1 more source

Interlink hybrid DC circuit breaker [PDF]

open access: yes, 2018
—To protect HVDC grids from DC faults, the concept of a hybrid DC circuit breaker is widely accepted due to its low conduction losses and fast interruption speed.
Li, Chuanyue, Liang, Jun, Wang, Sheng
core   +1 more source

Parameters of DC high-speed circuit-breakers

open access: yesMATEC Web of Conferences, 2018
DC high-speed circuit-breakers (HSCB) are the basic protection to cut off short-circuit and overload currents. People’s and railway infrastructure devices’ safety depend on their reliability and parameters.
Rojek Artur
doaj   +1 more source

Research on DC component decay time constant of 1000 kV AC filter circuit breakers in UHV converter station

open access: yesThe Journal of Engineering, 2019
In hierarchically connected UHV DC projects, the 1000 kV AC filter sub-bank in converter station is provided with two 500 kV circuit breakers. To determine the test DC component decay time constant when breakers break short-circuit current, relevant DC ...
Li Zhenqiang   +3 more
doaj   +1 more source

Overvoltage Impact on Internal Insulation Systems of Transformers in Electrical Networks with Vacuum Circuit Breakers

open access: yesEnergies, 2020
Vacuum circuit breakers are increasingly used as switching apparatus in electric power systems. The vacuum circuit breakers (VCBs) have very good operating properties. VCBs are characterized by specific physical phenomena that affect overvoltage exposure
Marek Florkowski   +3 more
doaj   +1 more source

Increasing the Sensitivity of Protections in Electrical Networks up to 1 kV by Using Microprocessor and Semiconductor Release Tripping Devices

open access: yesИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика, 2021
The paper deals with the problem of increasing the efficiency of the functioning of electric networks up to 1 kV, namely, the possibility of increasing the sensitivity of protections in networks up to 1 kV, which helps to reduce the protection response ...
A. Yu. Kapustsinski   +1 more
doaj   +1 more source

Home - About - Disclaimer - Privacy